PLACING THE MACHINE IN SERVICE
LUBRIFICATION
Always use of an air line lubricator with these machine. We recommended the
following Filter-Lubricator-Regulator Unit: FACOM N.580.
Every eight hours' operation, if a lubricator is not used on the compressed air
network, inject 1/2 to 1cm
through the machine's inlet connection.
3
3
Model
Chuck capacity
mm
V.445F
Ø 6
Model
Free speed
rpm
V.445F
20000
* k = measurement uncertainty in dB
WE, FACOM S.A.S., 6/8 RUE GUSTAVE EIFFEL - BP 99 - 91 423 MORANGIS CEDEX FRANCE, DECLARE UNDER OUR OWN RESPONSIBILITY THAT THE
PRODUCT V.445F – FACOM PNEUMATIC STRAIGHT GRINDER - 6 MM COLLET
- IS IN CONFORMITY WITH THE «MACHINERY» DIRECTIVE 2006/42/CE
- AND IS IN CONFORMITY WITH THE PROVISIONS OF THE HARMONISED EUROPEAN STANDARD EN ISO 11148-9: 2011
EN ISO 12100:2010
EN ISO 15744:2008
EN ISO 28927-12:2012
NU-V.445F_0915.indd 6
1
4
Motor power
rating
Pressure dB(A)
kW
0,75
89
Air consump-
Working
tion
pressure
l/min
bar
181
6,2
** k = measurement uncertainty in m/s²
CE DECLARATION OF CONFORMITY
EMERGENCY
GATE VALVE
2
5
Noise level
Power dB(A)
Pressure dB(C)
k*
k*
3
100
3
104
Weight
Dimensions
kg
mm
0,88
207x43x80
Vibrations level
m/s
2
k*
k**
3
0,99
0,59
20.01.2010
F
ACOM QUALITY MANAGER
9/8/2015 11:38:05 AM