FAN MOT OR ASSEMBLY
To register this product visit www.nutone.com
READ AND SAVE THESE INSTRUCTIONS
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:
1. Use this unit only in the manner intended by the manufacturer. If you have questions, contact the
manufacturer.
2. Before servicing or cleaning unit, switch power off at service panel. Lock or tag service panel to prevent power
from being switched on accidentally.
3. Installation work and electrical wiring (including switch location) must be done by a qualified person(s) in
accordance with all applicable codes and standards.
4. Provide sufficient air for proper combustion and exhausting of gases through the flue (chimney) of fuel burning
equipment to prevent backdrafting. Follow the combustion equipment standards such as those published
by the National Fire Protection Association (NFPA), the American Society for Heating, Refrigeration and Air
Conditioning Engineers (ASHRAE), and local codes.
5. This product may have sharp edges. Be careful to avoid cuts and abrasions during installation and cleaning.
6. When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.
7. Ducted fans must always be vented to the outdoors.
8. Not for use in kitchens.
9. Acceptable for use over a bathtub or shower when installed in a GFCI protected branch circuit.
10. Do not use this fan with any solid-state speed control device.
11. This unit must be grounded.
12. This unit must be installed into 8" x 7¼" fan housings that are marked "690" Series. For use only with NuTone
fan models 695 or 696N. No other usage has been tested or authorized by Broan-NuTone LLC.
CAUTION
1.
For general ventilating use only. Do not use to exhaust hazardous or explosive materials and vapors.
2.
Install fan at least five feet (1.52 m) above floor.
3.
To avoid motor bearing damage and noisy, unbalanced impellers, keep drywall spray, construction dust, etc. off
motor and impeller.
4.
Read specification label on product for information and requirements.
CLEANING & MAINTENANCE
•
For quiet and efficient operation, long life, and attractive appearance – lower or remove grille and vacuum
interior of fan with a dusting brush attachment.
•
The motor is permanently lubricated and never needs oiling. If the motor bearings make excessive or unusual
noise, replace the motor with the exact service motor. The impeller should also be replaced.
•
To remove blower assembly - See step 3.
OPERATION
Use an on/off switch to operate this ventilator.
WARRANTY
WARRANTY OWNER: Broan-NuTone warrants to the original consumer purchaser of its products that such
products will be free from defects in materials or workmanship for a period of one (1) year from the date of
original purchase. THERE ARE NO OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING, BUT NOT
LIMITED TO, IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.
During this one year period, Broan-NuTone will, at its option, repair or replace, without charge, any product
or part which is found to be defective under normal use and service. THIS WARRANTY DOES NOT EXTEND
TO FLUORESCENT LAMP STARTERS OR TUBES, FILTERS, DUCT, ROOF CAPS, WALL CAPS AND OTHER
ACCESSORIES FOR DUCTING. This warranty does not cover (a) normal maintenance and service or (b) any
products or parts which have been subject to misuse, negligence, accident, improper maintenance or repair
(other than by Broan-NuTone), faulty installation or installation contrary to recommended installation instructions.
The duration of any implied warranty is limited to the one year period as specified for the express warranty. Some
states do not allow limitation on how long an implied warranty lasts, so the above limitation may not apply to you.
BROAN-NUTONE'S OBLIGATION TO REPAIR OR REPLACE, AT BROAN-NUTONE'S OPTION, SHALL BE THE
PURCHASER'S SOLE AND EXCLUSIVE REMEDY UNDER THIS WARRANTY. BROAN-NUTONE SHALL NOT BE
LIABLE FOR INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES ARISING OUT OF OR IN CONNECTION
WITH PRODUCT USE OR PERFORMANCE. Some states do not allow the exclusion or limitation of incidental
or consequential damages, so the above limitation or exclusion may not apply to you. This warranty gives you
specific legal rights, and you may also have other rights, which vary from state to state. This warranty supersedes
all prior warranties.
WARRANTY SERVICE: To qualify for warranty service, you must (a) notify Broan-NuTone at the address or
telephone number below, (b) give the model number and part identification and (c) describe the nature of
any defect in the product or part. At the time of requesting warranty service, you must present evidence of
the original purchase date.
Date of Installation
Builder or Installer
Model No. and Product Description
IF YOU NEED ASSISTANCE OR SERVICE - CONTACT:
Broan-NuTone LLC Hartford, Wisconsin www.nutone.com 888-336-3948
Broan-NuTone Canada Mississauga, Ontario www.nutone.ca 877-896-1119
MODEL C350BN • C370BN
One Year Limited Warranty
INSTALLATION
1. Disconnect the electrical power supply and lock out the service panel for
the existing fan.
2. Remove the grille from the
existing fan.
Pull grille down to expose two
springs. Squeeze each spring
together and pull down again
to release springs from motor
plate slots.
3. Remove blower assembly
from
existing fan.
Unplug motor cord from
receptacle and remove screw
located next to receptacle. If
necessary, insert a straight-
blade screwdriver between
motor plate and side of housing
near the screw location and
gently pry housing away from
motor plate.
Pivot blower assembly down
and out.
4. Check existing housing.
Vacuum the interior of the
existing fan housing with a
dusting brush attachment.
Examine the housing to make
sure it is securely fastened
to the building structure and
free of any holes caused by
corrosion. The receptacle
must be intact. If any damage
is found, do not continue
installation of this product.
Contact a qualified person(s)
for repair.
5. Install new blower
assembly into existing fan
housing.
Insert two motor plate tabs
into slots in housing and pivot
blower assembly up until it is
touching the wiring box. Secure
in place with existing screw.
Plug in motor.
6. Install grille.
Squeeze one grille spring
together and insert it into the
matching slot in motor plate.
Repeat with the other grille
spring.
Push grille until it is tight
against ceiling or wall.
Rev. 08/2007
GRILLE
SCREW
SIDE OF
HOUSING
MOTOR PLATE
SCREW
GRILLE SPRING
MOTOR
PLATE
GRILLE
SPRING
2 TABS
&
SLOTS
99044083B