ONLY ONE ELECTRICAL STOVE CAN BE INSTALLED IN THE SAUNA.
All service operations must be done by professional maintenance personnel. Electricity
supply to the heater must be switched off from the fuse panel before any service measures.
NM:
4,5
125
X min.
kW
(mm)
6
125
kW
9
175
kW
Figure 2.
3. INSTALLATION:
-
Fasten the mounting plate to the wall with the screws which follow the delivery
according to the picture 2.
NM: CHANGE FROM RIGHT TO LEFT HAND (only if necessary)
Note! If you want to change from right to left hand work according to Stages 1, 2 and 3. If there
is no need to change move to Stage 4.
Stage 1:
-
Loosen the anchor screws of the coupling box.
-
Gently pull of the adjusters, and open the two outermost screws that are attached to the control
panel and found under the adjusters.
-
Open the optional adjuster's cover plate's screws which are on the other side of the junction box
(Figure 3).
Stage 2:
-
Unscrew the attaching screw connecting the middle resistor and the terminal block which is located
at the bottom of the junction box. This will enable you to turn the leg of the terminal block to the side
from underneath the screw (Figure 4).
Stage 3:
-
Turn the adjusting module carefully around with its cords attached and install the axis of the adjuster
through the holes on the other side of the junction box.
-
Screw together the terminal block and the cover plate of the optional adjusters facing each other.
-
Finally, attach the bottom plate of the junction box and adjusters to their place (Figure 5).
Figure 3
MINEX:
Figure 4
Figure 5