To reduce the risk of electric shock, insure electricity has been
1.
turned off at the circuit breaker or fuse box before beginning.
All wiring must be in accordance with the National Electrical
2.
Code ANSI/NFPA 70-1999 and local electrical codes.
Electrical installation should be performed by a qualified
licensed electrician.
CAUTION: To reduce the risk of personal injury, use only the
3.
screws provided with the electrical box.
The outlet box and support structure must be securely
4.
mounted and capable of reliably supporting 35 lbs. (15.9 kg).
Use only cUL Listed outlet boxes marked "Acceptable for Fan
Support of 35 lbs. (15.9 kg) or less."
CAUTION: The fan must be mounted with a minimum of 7
5.
feet clearance from the trailing edge of the blades to the floor.
Do not wait for the fan to stop before pressing the reverse
6.
button. The fan will not reverse direction if the fan is not
moving.
Avoid placing objects in path of the blades.
7.
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK OR PERSONAL
INJURY, MOUNT TO OUTLET BOX MARKED "ACCEPTABLE FOR FAN
SUPPORT OF 35LBS. (15.9 KG) OR LESS", AND USE SCREWS PRO-
VIDED WITH THE OUTLET BOX.
TO REDUCE THE RISK OF PERSONAL INJURY, DO NOT BEND THE
BLADE BRACKETS (ALSO REFERRED TO AS ("FLANGES") DURING
ASSEMBLY OR AFTER INSTALLATION. DO NOT INSERT OBJECTS IN
1. Safety Rules
THE PATH OF THE BLADES.
READ AND SAVE THESE INSTRUCTIONS
To avoid personal injury or damage to the fan and other items,
8.
be cautious when working around or cleaning the fan.
Do not use water or detergents when cleaning the fan or fan
9.
blades. A dry dust cloth or lightly dampened cloth will be
suitable for most cleaning.
After making electrical connections, spliced conductors should
10.
be turned upward and pushed carefully up into electrical box.
The wires should be spread apart with the grounded conductor
and the equipment-grounding conductor on one side of the
electrical box and ungrounded conductor on the other side of
the electrical box.
Electrical diagrams are for reference only. Light kits that
11.
are not packed with the fan must be UL Listed and marked
suitable for use with the model fan you are installing. Switches
must be UL General Use Switches. Refer to the instructions
packaged with the light kits and switches for proper assembly.
All set screws must be checked and retightened where
12.
necessary before installation.
WARNING: To reduce the risk of fire or electric shock, this
13.
fan should only be used with speed controller UC7312RE,
manufactured by Rhine Electronic Co., Ltd.
TO REDUCE THE RISK OF SHOCK, THIS FAN MUST BE INSTALLED
WITH AN ISOLATION WALL CONTROL/SWITCH.