Descargar Imprimir esta página

Johnson ARGON Serie Manual De Instrucciones página 35

Publicidad

Idiomas disponibles

Idiomas disponibles

2. PRODUCT INTRODUCTION
Nomenclature
ARGON # #
① ② ③ ④
The nomenclature can end in BUT that the product is compatible with LPG gas while
if it ends in GN, it means that the product is compatible with Natural Gas.
This manual is applicable to the forced-exhaust water heaters manufactured by this
company.
2.2 Technical Performance Parameters (Table 1)
Model
CE-Pin
Power Consumption
Rated Voltage
Frequency
Gas
Gas Category
Gas Type
Gas pressure
Power
Nominal Heat Input(Q)
Nominal Useful Output
Minimum Heat Input
Minimum Useful Output
Efficiency of energy sources
Water supply pressure
Max. water pressure
Min. water pressure
Max. water pressure
Min. water pressure
Max.waterflow(2bar)
Min.waterflow(2bar)
2.1
NOTE
ARGON11BUT
W
45
V.ac
230~
50
Hz
I
I
3B/P(30)
3P(37)
G30/G31 G30
G31
30
mbar
37
kW
22
kW
19.2
kW
9.5
kW
7.0
8
5%
bar
10
bar
0.2
MPa
1.0
MPa
0.02
L/min
13.0
L/min
8.0
4
ARGON11GN
2575DM30059
45
230~
50
I
I
3+(28-30/37)
2H
G31
G20
28-30
20
37
22
19.2
9.5
8.2
8
5%
10
0.2
1.0
0.02
13.0
8.0
V.3

Publicidad

loading

Este manual también es adecuado para:

Argon11butArgon11gn