Operations
Check after each readjustment that the screws are tightly
fixed so that safe operating of the drilling stand is possible.
Mounting of the turnstile
! Mount the turnstile (1) on the right
or left side of the carriage (2) depend-
ing on the kind of work to be per-
formed.
! Check whether the turnstile (1) is
fixed tightly.
Mounting of the stand
Fixing the mount on the floor by vacuum
Do not use vacuum fixing on walls or overhead. Vacuum fixing may only be
used if the area to be drilled is level, free of pinholes and cracks, otherwise this
method cannot be applied. For the vacuum fixing you need the vacuum set P-
54190, vacuum pump and –hose. They are available on request.
Connect the drilling stand and the vacuum pump by means of the vacuum hose.
Bring the drilling stand into the correct position and switch the pump on.
Check whether the four levelling screws are completely turned back and a vac-
uum of min. -0.8 bar is achieved.
Screw the plug-in nipple into
the foot plate, to which previ-
ously a seal strip has been
applied. Insert the vacuum
handle with the seal.
Fasten the vacuum handle with a
washer and hexagon hollow head plug
M8x30 and insert the foot sealing into
the corresponding notch.
14
Click