7. Starting, operation
Specifications
Response time
Current consumption
Insulation voltage
Non-linearity
2)
Accuracy
Zero offset
Hysteresis
Non-repeatability
Long-term drift
Signal noise
1
Operating instructions/Betriebsanleitung/Mode d'emploi/Instrucciones de servicio
Model A-10
0 ... 5 V, 3-wire
1 ... 5 V, 3-wire
0.5 ... 4.5 V, 3-wire
{Other signal output on request}
ms
< 4
mA
Signal current (max. 25) for current output
Max. 8 for voltage output signal
1)
VDC
500
1)
For power supply, use a circuit with energy limitation (EN/UL/IEC
61010-1, section 9.3) with the following maximum values for the
current: with UB = 30 V (DC): 5 A. Provide a separate switch for the
external power supply. Alternative for North America: The connection
may also be made to „Class 2 Circuits" or „Class 2 Power Units"
according to CEC (Canadian Electrical Code) or NEC (National Elec-
trical Code).
≤ ± 0.3
% of span
≤ ± 0.6
Adjusted in vertical mounting position with lower pressure connection.
≤ ± 0.5
% of span
≤ ± 0.6
≤ ± 1.0
2)
Including non-linearity, hysteresis, zero point and full scale error (corresponds to
error of measurement per IEC 61298-2).
% of span
≤ 0.15 typ., ≤ 0.4 max., (with non-linearity 0.3 %)
≤ 0.5 typ., ≤ 0.8 max.,
≤ 0.16
% of span
% of span
≤ 0.1
≤ 0.1
% of span
≤ 0.3
% of span
RA > 5 k
RA > 5 k
RA > 4.5 k
according to IEC 61298-2
(with non-linearity 0.3 %)
(with non-linearity 0.3 % and with signal output 0 ... 5 V)
(with non-linearity 0.6 %)
(with non-linearity 0.6 %)
according to IEC 61298-2