Mechanical Connection - GREISINGER A-10 Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

7. Starting, operation

Mechanical connection

max.
50 Nm
For Model A-10 with straight thread the sealing ring is included in delivery.
Please refer to our data sheet "Pressure gauge sealing washers AC 09.08" in product
catalog Pressure and Temperature Measurement for details about sealing washers.
When mounting the instrument, ensure that the sealing faces of the instrument and
the measuring point are clean and undamaged.
Screw in or unscrew the instrument only via the flats using a suitable tool and the
prescribed torque. The appropriate torque depends on the dimension of the pressure
connection and on the sealing element used (form/material). Do not use the case as
working surface for screwing in or unscrewing the instrument.
When screwing the transmitter in, ensure that the threads are not jammed.
For tapped holes and welding sockets please see Technical Information IN 00.14
Types of sealings
according to EN 837
NPT, R and PT are self-sealing thread types.
Operating instructions/Betriebsanleitung/Mode d'emploi/Instrucciones de servicio
Product label (example)
S #
P #
according to DIN 3852-E
Power Supply
Signal
Serial No.
Product No.
Coded manufacture date
PIN assignment
according to NPT
GB
7