Descargar Imprimir esta página

Roca IN-WASH INSIGNIA A803104001 Manual De Instrucciones página 50

Publicidad

Idiomas disponibles

Idiomas disponibles

PROBLEM
The nozzle does not move backwards.
The drying stops or it does not work.
The temperature of the drying air is not
warm enough.
The seat moves when sitting down.
Water comes out through the nozzle door
and the function is not activated
* Should the problem persist, please call the Technical Assistance.
6. TECHNICAL FEATURES
6.1 FEATURES / SPECIFICATIONS
SPECIFICATIONS
Model
Flush volume
Power supply
Frequency
Max. power input
Heat output
Temperature range
Water pressure
Cleaning
Drying
Length of the connecting cable
POSSIBLE CAUSE
The power supply has been cut.
The engine of the nozzle has lost its
position.
The pre-set drying time of 3 minutes has
expired.
The infrared sensor has stopped
detecting the user. If the position during
use is too forward, the device might stop
detecting the user.
The temperature of the drying air is set to
room temperature.
The air heater is not working.
The rear brackets of the seat are not tight
enough.
Water heater
Hot air dryer
Service temperature
Water temperature 4 levels
Temperature of the warm air dryer 4
levels
Storage temperature
Flow perineal position
Flow anal position
Safety devices
Air speed of the dryer
Safety device
50
SOLUTION
Restore the nozzle automatically.
Reset the product. (See 3.6). *
This is normal. Reactivate the drying
function.
Sit down correctly. Reactivate the
cleaning function. *
Increase the temperature by means of
the remote control.
*
Tighten the rear brackets of the seat.
*
In-Wash Insignia
4,5L / 3L
220-240V AC
50/60Hz
1700W
1650 W
300 W
10ºC / 30ºC
OFF / 33 / 36 / 39ºC
OFF / 40 / 50 / 60ºC
-10ºC / 60ºC
0,05 Mpa / 0,8 MPa (0,5 bar - 8 bar)
0,45 – 0,55 – 0,65 l/min
0,65 – 0,75 – 0,85 l/min
Fusible y Termostato
8,5 m/s
Fusible
1,5 M

Publicidad

loading

Este manual también es adecuado para:

In-wash insignia a803105001