Classic schema : all devices
Schema example + reduced power :
Reduced power : allows for example to make pens for animals in a state of temporary weakness (after calving, ... etc.)
or susceptible animals while maintaining other enclosures at maximum power.
Example of a loop connection :
When one end of the fence is connected to terminal 3 of the unit, the LED B allows to monitor the proper functioning of
this fence.
In this configuration :
- if the green LED (B) lights, the loop is correct (a circuit is achieved)
-If the green indicator (B) is not lit, the wire is cut.
In this case the two segments of the connexion the outward pulses remain electrified.
But that of the return to the energiser remains at a reduced power.
Secur 2400/2600
Secur 2600 D/2600 DAC
wire connected to
« full output terminal »
wire connected to
« reduced output terminal »
Secur 2400/2600
Secur 2600 D/2600 DAC
B
3
3
insulator
insulator
insulator
insulator
Fence wire connected to the "HIGH OUTPUT
POWER "
and then looped
to the terminal reduced output
7
insulator
insulator
insulator
insulator