DANGER: Do not handle pressurized hoses. Escaping
oil under pressure can penetrate the skin, causing
serious injury. If oil is injected under the skin, see a
doctor immediately.
WARNING: Only use hydraulic cylinders in a coupled
system. Never use a cylinder with unconnected couplers. If
the cylinder becomes extremely overloaded, components
can fail catastrophically causing severe personal injury.
WARNING: BE SURE SETUP IS STABLE BEFORE
LIFTING LOAD. Cylinders should be placed on a fl at
surface that can support the load. Where applicable, use
a cylinder base for added stability. Do not weld or otherwise
modify the cylinder to attach a base or other support.
Avoid situations where loads are not directly centered
on the cylinder plunger. Off -center loads produce
considerable strain on cylinders and plungers. In
addition, the load may slip or fall, causing potentially dangerous
results.
Distribute the load evenly across the entire saddle surface.
Always use a saddle to protect the plunger.
IMPORTANT: Hydraulic equipment must only be serviced
by a qualifi ed hydraulic technician. For repair service,
contact the Authorized ENERPAC Service Center in your
area. To protect your warranty, use only ENERPAC oil.
WARNING: Immediately replace worn or damaged parts
by genuine ENERPAC parts. Standard grade parts will
break causing personal injury and property damage.
ENERPAC parts are designed to fi t properly and withstand high
loads.
3.0 SPECIFICATIONS
Load Ratings for WR-5
Maximum System
Pressure
psi (bar)
10,000 (689)
Load Ratings for WR-15
Model
Capacity
No.
Tons
WR-5
1.00
WR-15
0.75
A-92
1.00
Hyquip Limited New Brunswick Street Horwich Bolton Lancashire BL6 7JB UK
Company Registered in England No: 4167649 VAT Registration No: 732 5692 25 BS EN ISO 9001:2008 No: LRQ 0964389
4.0 INSTALLATION
spreader arms open in a radial motion and the spreader could
become a projectile if circular or orbital motion also occurs.
WR-5 and WR-15
Attach hose to 3/8" NPT port. Connect mating coupler halves
together hand tight only. Using tools will damage the coupler.
premature failure.
A-92
Attach an included A-13 or A-102F smooth saddle to the cylinder
plunger before attaching the spreader to the cylinder collar
threads. Hand tighten the saddle and the spreader.
IMPORTANT: An Enerpac RC-102 cylinder is recommended for
Maximum Rated Load
use with the spreader. However, an RC Series cylinder of longer
at Tips
lbs. (kg)
stroke (RC-104 through RC-1014) can be used if an RC-102
cylinder is not available. The RC-101 cylinder should not be used
2,000 (907)
because its stroke length is insuffi cient for use with the spreader.
Eff ective
A
B
Area
in 2 (cm 2 )
in. (cm)
in. (cm)
1.00
8.78
3.70
(6,45)
(22,3)
(9,40)
2.25
21.7
11.50
(14,5)
(55,0)
(29,21)
---
9.63
6.25
(24,5)
(15,88)
2
+44 (0)1204 699 959
enquiries@hyquip.co.uk
www.hyquip.co.uk/web/index
Spread at Tips
Maximum System
Pressure
in. (cm)
psi (bar)
0 (0)
9,000 (620)
3 (8)
9,000 (620)
6 (15)
6,000 (415)
9 (23)
3,000 (205)
11.5 (29)
1,000 (70)
Load Ratings for A-92
Cylinder Required
Maximum System
(Note: cylinder
Pressure
sold separately)
psi (bar)
Enerpac RC-10 Series
5,000 (344)
(All models except RC-101)
WARNING: DO NOT USE the spreader on pipe fl anges
or in applications where one or both objects can move
in a circular or orbital motion. General purpose
CAUTION: Position hoses to avoid sharp bends,
kinks, and sharp impacts from objects because they
may cause wear or damage to the hose, leading to
C
Oil
Capacity
in 3 (cm 3 )
in. (cm)
0.38
0.61
(0,97)
(10,0)
1.26
3.91
(3,20)
(64,1)
1.38
---
(3,51)
Maximum Rated Load
at Tips
lbs. (kg)
1,500 (682)
Maximum Rated
Load at Tips
lbs. (kg)
2,000 (907)
Wt.
lbs. (kg)
5.00
(2,27)
25.00
(11,34)
8.00
(3,63)