PROBLEM
Side Burner does not light.
Flame is low in "HI" position.
Push button ignition does not work.
If problems cannot be corrected by using these methods, please contact the Customer Service Representative in your area using the contact information on our
web site. Log onto www.weber.com
SIDE BURNER MAINTENANCE
WARNING: All gas controls and supply valves should be in
the "OFF" position.
Make sure black wire is connected between the igniter and electrode.
Make sure white wire is connected between the igniter and grounding clip.
Spark should be a white/blue color, not yellow.
1)
Igniter Wire
2)
Ground wire
3)
Burner
WEBER
®
SPIDER /INSECT SCREENS
Y
®
our Weber
gas barbecue, as well as any outdoor gas appliance, is a target for spiders
and other insects. They can nest in the venturi section (1) of the burner tubes. This
blocks the normal gas fl ow, and can cause the gas to fl ow back out of the combustion
air opening. This could result in a fi re in and around the combustion air openings, under
the control panel, causing serious damage to your barbecue.
The burner tube combustion air opening is fi tted with a stainless steel screen (2) to
prevent spiders and other insects access to the burner tubes through the combustion air
openings.
We recommend that you inspect the Spider/Insect screens at least once a year.
(See Section "Annual Maintenance".) Also inspect and clean the the Spider/Insect
screens if any of the following symptoms should ever occur:
1)
The smell of gas in conjunction with the burner fl ames appearing yellow and lazy.
2)
Barbecue does not reach temperature.
3)
Barbecue heats unevenly.
4)
One or more of the burners do not ignite.
Failure to correct the above mentioned symptoms may result
in a fi re, which can cause serious bodily injury or death, and
cause damage to property.
WWW.WEBER.COM
®
All manuals and user guides at all-guides.com
SIDE BURNER TROUBLESHOOTING
CHECK
Is gas supply off?
The excess fl ow safety device, which is part
of the barbecue to cylinder connection, may
have activated.
Is the fuel hose bent or kinked?
Does burner light with a match?
®
.
SIDE BURNER MAINTENANCE
Side Burner Grate
Burner Grate
Side Burner cap
e Burner Cap
Side Burner Ring & Head
r Ring & Head
Igniter Electrode
niter Electrode
Control Knob
Control Knob
Igniter Button
Igniter
DANGER
Turn supply on.
To reset the excess fl ow safety device turn all burner control knobs and the cylinder
valve off. Disconnect the regulator from the cylinder. Turn burner control knobs to
START/HI. Wait at least 1 minute. Turn burner control knobs to "OFF". Reconnect
the regulator to the cylinder. Turn cylinder valve on slowly. Refer to "Lighting Instruc-
tions".
Straighten hose.
If match lights burner, check igniter (see Sideburner Maintenance).
MAINTENANCE
17
CURE
(3)
(2)
(1)
(2)
1
2
17
(1)