C. Installation instruction
Note:
1. This heat pump unit can be installed at veranda, hallway or other place where is easy to install and
stable. The air inlet & outlet are at the top side, main unit should not be placed at an open air.
Avoid the rain or debris to enter the vents. The air inlet and outlet can connect the φ150mm air
duct. As below:
(Fig.1)
2. When install as Fig.1, only connect the air inlet or outlet, the unit should be installed
at a place of ventilation, and the side connected with water pipes should have enough space.
Then, if the unit is installed besides the room, the air outlet duct can be connected to the room for
exchanging fresh air and cooling function; If the unit is installed in the room, it can be pulled out
room's air for ventilation function.
If install as Fig. 2, the unit can be installed by the middle of the wall, and connect the air inlet and outlet
3.
pipe for air exchange. The distance of the unit and wall or other obstacle should not be too short. Keep a
certain distance.
If install as Fig. 3, the unit is installed outside the
4.
room, the air inlet and outlet is connected indoor
for air exchange (and cooling). In this way, the
indoor air inlet and outlet should have a distance
≥2m to avoid mix air.
Because the air outlet comes with cooling air, the
5.
CLOCK
ON/OFF
surface of the pipe may have condensation water,
TIMER
MODE
it's necessary to insulate the indoor outlet pipe to
prevent water leakage.
6. Heat pump water heater unit must be placed upright,
and installed on a solid place where can be able to
withstand the weight over 360kgs. Supporting surface
should be evenness (obliquity less than 2º)
7. When install the unit, there should has some
measures of sound insulation and shockproof in order
not to affect neighbors.
CLOCK
ON/OFF
TIMER
MODE
≥600mm
≥600mm
(Fig.2)
≥600mm
3
CLOCK
ON/OFF
TIMER
MODE
≥500mm
(Fig. 3)
V.1