Supplement
Influence of the ambient temperature
in the range 0 ... +50 °C
-
(+32 ... +122 °F)
in the range of -20 ... 0 °C
-
(-4 ... +32 °F)
Indications
Indication of the function
LED yellow
-
LEd response current
-
Ambient conditions
Ambient temperature
Storage and transport temperature
Climatic class
Electrical protective measures
Protection rating
Overvoltage category
Protection class
Electrical separating measures
Reliable separation according to VDE 0106 part 1 between all circuits
Reference voltage
-
Isolation resistance
-
Functional safety (SIL)
The instrument can be used in safety-instrumented systems according to IEC 61508/IEC 61511-1
(service proven).
This is possible up to SIL2 in a single channel architecture (1oo1D), and up to SIL3 in a multiple channel,
redundant architecture (homogenously but also diversitary redundant).
If the instrument is already ordered with SIL qualification, the corresponding Safety Mannual will be
supplied in which you can find detailed information to "Functional Safety (SIL)".
If the instrument is ordered without SIL qualification, you can find the corresponding Safety Manual under
"www.vega.com", "Downloads", "Approvals".
Approvals
Depending on the version, instruments with approvals can have different technical data.
For these instruments, the corresponding approval documents have to be taken into account. These are
part of the delivery or can be downloaded under www.vega.com via "VEGA Tools" and "serial number
search" as well as via "Downloads" and "Approvals".
20
≤ 0.1 %/10 K
≤ 0.2 %/10 K
lights with closed output circuit
< 2 mA
-20 ... +50 °C (-4 ... +122 °F)
-20 ... +70 °C (-4 ... +158 °F)
according to EN 60654-1, class B2
IP 20
II
I
253 V
3.75 kV
VEGATRENN 149A Ex