Failure removal
Defect
Compressor not starting ater being
switched on
Ater reaching the closed pressure,
the compressor runs or buzzes or
a short time and then switches o
automatically
Compressor running constantly
Compressed air is released rom the
discharge valve under the pressure
switch when the appliance is being
operated
Ater reaching the cut-o pressure,
air is released rom the discharge
valve under the pressure switch
until the closing pressure is reached
Compressor gets started too oten
Saety valve blowing o
Compressor getting warm too much Air supply is not sucient
Compressor being overheated and
keeps switching o
Causes
Pressure in the air jet exceeds the
closing pressure
Deective supply
Deective pressure switch
Worn carbons
Electric cable is too long or its cross
section is too small
Suction lter is very dirty
Pneumatic tools have high air
consumption
Leaking on the compressor
Compressed-air pipeline leaking
Drain valve is open or missing
Discharge valve is leaking
Check valve insert is leaking or
deective
Check valve is damaged
Too much condensate in the air jet
Compressor is overloaded
Pressure in the air jet exceeds the set
cut-o pressure
Saety valve is deective
Cooling ns on the cylinder (cylinder
head) are dirty
Too long time o appliance operation Switch the compressor o
Compressor is overloaded
Compressor is deective
Compressor under undervoltage
Outdoor temperature o 35°C
Measure
Release the pressure in the air jet so
that the pressure switch gets automa-
tically switched on
Have the current supply checked by
an authorised person
Have the pressure switch replaced by
an authorised person (Güde service
centre)
Replace the carbons
Check the length and cross section o
the electric cable
Clean or replace the suction lter
Check the pneumatic tool air con-
sumption;
seek an authorised compressed air
dealer
Localise the leaking, contact the Güde
service centre
Contact the Güde service centre
Close or insert the drain valve
Clean or replace the discharge valve
Clean or replace the check valve insert
14
Replace the check valve
Drain the condensate
Have the pressure switch adjusted/re-
placed by an authorised person (Güde
service centre)
Replace the saety valve or contact the
Güde service centre
Make sure sucient air supply and
outlet (minimum distance rom wall is
40 cm) is provided
Clean the cooling ns on the cylinder
(cylinder head)
Contact the Güde service centre
Contact the Güde service centre
Contact the Güde service centre