Descargar Imprimir esta página

ELICA Lien Golden 604BL Montaje Y Modo De Empleo página 22

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 56
ERROR CODE
ER03 - the hob turns off
after 10 seconds and
beeps permanently
ER47
U400
E2
E3
ER20,ER22
E5,E6,E8,E9
EA,E/H
Customer service
Before contacting Customer Service
1.Check that you cannot solve the problem yourself based on
the points described in "Troubleshooting".
2.Switch the device off and on again to see if the problem
resolves itself.
If, after the above checks, the fault persists, contact the
nearest Customer Service.
Troubleshooting
DESCRIPTION
Permanent pressure on the
command zone
Communication with the electric
network is faulty (the control panel
switches off - the cooking zones
no longer respond)
The hob connection is not of the
correct voltage (wrong
connection/overvoltage)
The command zone switches off
due to too high a temperature
Container unsuitable
Call customer service and report the error code
POSSIBLE CAUSES
Water or kitchen
utensils on the
command zone
The power cable was
incorrectly connected
or is faulty
A different voltage is
detected from that of
the connection
The temperature inside
the electronic parts is
too high
Loss of magnetic
properties
22
ERROR REMOVAL
Clean the command
zone
Disconnect the hob
from the mains and
check the connection
Disconnect the hob
from the mains and
check the connection
Wait for the hob to
cool before reusing it
Remove the pan