Descargar Imprimir esta página

Vortice LINEO 125 ES Manual De Instrucciones página 10

Ocultar thumbs Ver también para LINEO 125 ES:

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 20
ENGLISH
Selecting the operating mode
Two-speed mode:
cut off the power supply
set the dip-switch SW2 indicated in
the figure:
Int.2=ON; Int.3=OFF
Int.4=OFF
Adjustable speed mode:
cut off the power supply
set the dip-switch SW2 indicated in
the figure:
Int.2=OFF; Int.3=OFF
Int.4=OFF
Setting the V1 and V2 values
The appliance leaves the factory with default nominal
settings V1=V
, V2=V
MIN
Values V1 and V2 can be adjusted as follows:
- cut off the power supply
- set the dip-switch SW2 indicated
in the figure:
Int.1=OFF
Int.4=ON
- restore the power supply. The motor automatically
runs at the V1temp speed
- set Int.1=ON. This produces two
effects:
the V1temp value is saved as a
new V1;
the motor automatically runs at V2temp;
- use the trimmer (see figure) to set V2temp to the
desired value, between the saved V1 + 100Rpm and
Vmax;
- set Int.1=OFF. This produces two
effects: the V2temp value is saved
as a new V2;
the motor automatically runs at
V1temp
- cut off the power supply
- set Int.4=OFF to lock the V1 and
V2 values
10
ON
OFF
1 2 3 4
ON
OFF
1 2 3 4
MAX
ON
OFF
1 2 3 4
- use the trimmer (see
figure) to set V1temp to the
desired
value,
between
V1nom and the saved V2 –
100Rpm
ON
OFF
1 2 3 4
ON
OFF
1 2 3 4
ON
OFF
1 2 3 4
Restoring nominal values
If necessary, the nominal factory-set values for V1 and
V2 can be restored using the following procedure:
- cut off the power supply
- set the dip-switch SW2 indicated
in the figure:
Int.3=ON
- restore the power supply:
V1 and V2 are automatically
restored
to
the
corresponding to the selected model, as described
above. The restoring of nominal values is indicated
by two quick flashes of an LED on the card.
The motor is deactivated automatically
- cut off the power supply
- reset
the
dip-switch
indicated in the figure:
Int.3=OFF
Operation
Depending on the mode selected during installation:
- two-speed
mode:
continuously; two speeds V1 and V2 can be selected
using an external switch
- adjustable speed mode: the appliance can operate
at a speed which is adjusted between 300 Rpm and
Vmax (via an external potentiometer). The Vortice
ON/OFF control box + potentiometer (code 12826,
on request) can also be used.
Maintenance / Cleaning
Fig. 27, 28, 29
ON
OFF
1 2 3 4
nominal
factory-set
SW2
ON
OFF
1 2 3 4
the
appliance
operates
values

Publicidad

loading