Installation Instructions/Instrucciones de Instalación
8. Finish the wall around the plaster guards. Make sure the valve is at the proper depth before finishing the wall.
9. Once the surrounding wall is finished remove the plaster guards.
10. Apply a bead of silicone sealant onto the back edge of the backplate and slide into place over the cartridge
bodies. Using a clean rag, wipe off any excess silicone.
11. Loosen the set screw inside the thermostatic temperature control handle (A). Slide it on to the cartridge stem and
tighten the set screw. Install finished cap.
12. Loosen the set screw inside the volume handle (B). Slide it onto the cartridge in the proper position, tighten
the set screw, and install the finished cap. Repeat for diverter handle (C).
Thermostatic handle
=38°C - 100°F
Factory set 100°F
The valve comes from the factory with the water temperature set to 100° F and STOP button as anti-scalding device.
If the water temperature at the STOP button is not set to 100° F, remove the thermostatic handle and safety stopper,
calibrate the water temperature to 100° F by rotating the cartridge stem and measuring the water temperature
with a thermometer, then reinstall the safety stopper and handle.
Setting the Temperature Range
Turn clockwise for temperature
lower than 100°F
C
B
A
<38°C - 100°F
5
PRESS AND TURN
>38°C - 100°F
MAX 49°C - 120°F
Press button and turn counter-
clockwise for temperature
higher than 100°F