Preferably position the
GWDS amidships and
lengthwise in the ship.
Install the GWDS while the ship is at rest and then fit the GWDS on
a horizontal surface.
The GWDS is guaranteed to work correctly at angles up to 10˚ from
fore to aft and 20˚ athwartships.
4.2 Summary of connections
1.
Shower
2.
Washbasin
3.
Air conditioning
4.
Drain
2
1
4.3 Connection 1 (shower)
A shower can be connected to the side connection.
• Using a sharp knife, remove the closed side of the connection
piece (A).
Installation and user manual GWDS
• Fit the connection piece (A) over the side connection and clamp
this with the plastic clamp (B).
• Fit a reducing piece (not supplied) of ø 40 mm to the correct hose
diameter in the connecting piece (A) and clamp this with the plas-
tic clamp (B).
• Fit the hose.
4.4 Connection 2 (washbasin)
• Using a sharp knife, cut open one of the circles indicated.
Trim the cut surface well.
Remove any sawdust from the GWDS.
4
• Place the connection piece (C) in the opening.
• Place a ø 40 mm reducing coupling (not supplied) to the desired
hose diameter in the connection piece (C) and attach it with the
help of the hose clamp (D).
3
• Fit the hose.
2
4.5 Connection 3 (air conditioning)
• Drill an ø 8 mm hole in the hose connection, through the con-
tainer.
• Attach the ø 12 mm hose.
ENGLISH
9