6.8 Adjusting the pressure: (Fig. 1,2)
•
You can adjust the pressure on the pressure
gauge (6) using the pressure regulator (7).
•
The set pressure can be taken from the quick-
lock coupling (5).
6.9 Setting the pressure switch
The pressure switch is set at the factory.
Switch-on pressure 8 bar
Switch-off pressure 10 bar
7. Replacing the power cable
Danger!
If the power cable for this equipment is damaged,
it must be replaced by the manufacturer or its
after-sales service or similarly trained personnel
to avoid danger.
8. Cleaning and maintenance
Danger!
Pull the power plug before doing any cleaning
and maintenance work on the appliance.
Warning!
Wait until the compressor has completely
cooled down. Risk of burns!
Warning!
Always depressurize the tank before carrying
out any cleaning and maintenance work.
Danger!
After use, always switch off the equipment
immediately and pull out the power plug.
8.1 Cleaning
•
Keep the safety devices free of dirt and dust
as far as possible. Wipe the equipment with a
clean cloth or blow it with compressed air at
low pressure.
•
We recommend that you clean the appliance
immediately after you use it.
•
Clean the appliance regularly with a damp
cloth and some soft soap. Do not use cleaning
agents or solvents; these may be aggressive
to the plastic parts in the appliance. Ensure
that no water can get into the interior of the
appliance.
•
You must disconnect the hose and any
spraying tools from the compressor before
cleaning. Do not clean the compressor with
water, solvents or the like.
Anl_TE_AC_270_50_10_SPK8.indb 29
Anl_TE_AC_270_50_10_SPK8.indb 29
GB
8.2 Condensation water (Fig. 1)
Important. To ensure a long service life of the
pressure vessel (2), drain off the condensed water
by opening the drain valve (11) each time after
using. Check the pressure vessel for signs of rust
and damage each time before using. Do not use
the compressor with a damaged or rusty pressure
vessel. If you discover any damage, please con-
tact the customer service workshop.
Important!
The condensation water from the pressure
vessel will contain residual oil. Dispose of the
condensation water in an environmentally
compatible manner at the appropriate collec-
tion point.
8.3 Safety valve (10)
The safety valve has been set for the highest per-
mitted pressure of the pressure vessel. It is prohi-
bited to adjust the safety valve or remove its seal.
Actuate the safety valve from time to time to en-
sure that it works when required. Pull the ring with
suffi cient force until you can hear the compressed
air being released. Then release the ring again.
8.4 Check the oil level at regular intervals
Place the compressor on a level and straight sur-
face. The oil level must be between the two marks
MAX and MIN on the oil oil level window (Fig. 12).
Changing the oil: Recommended hydraulic oil:
SAE 5W/40 or an alternative of the same quality.
It should be refi lled for the fi rst time after 100
hours of operation. Thereafter the oil should be
drained and refi lled after every 500 hours in ser-
vice.
8.5 Changing the oil
Switch off the engine and pull the mains plug out
of the socket. After releasing any air pressure you
can unscrew the oil drainage screw (15) from the
compressor pump. To prevent the oil from running
out in an uncontrolled manner, hold a small metal
chute under the opening and collect the oil in a
vessel. If the oil does not drain out completely, we
recommend tilting the compressor slightly.
Dispose of the old oil at a drop-off point for
old oil.
When the oil has drained out, re-fi t the oil draina-
ge screw (15). Fill new oil through the oil fi ller ope-
ning (27) until it comes up to the required level.
Then replace the oil sealing plug (14).