Installation And Assembly; Customer Responsibilities; Characteristics Of The Place Of Machine Installation; Machine Space Limits - Veetsan VDH63 Manual De Instrucciones Para El Uso

Lavavajillas con tapa
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

E
IMPORTANT!
Machine installation operations must only
be carried out by specialized Technicians
provided with all the appropriate personal
protection
equipment
gloves, glasses, overalls, etc.), tools, uten-
sils and ancillary means.
IMPORTANT
Before servicing, disconnect the electrical main
switches and place a red tag at the disconnect
switch to indicate work is being done on that circuit.
E1

Customer responsibilities

The Customer must provide for the following:
-
Install a disconnecting switch with a capacity at least
equal to that given in the technical data table, a 30mA
residual current circuit breaker and an overcurrent
device (magnetothermal cut-out with manual reset or
fuse) between the appliance and the mains power
outlet. The chosen device must be lockable in the
open position in case of maintenance.
-
install an adequate electrical power supply ahead of
the machine, according to the equipment's technical
specifications (Table 1 and C2 "Characteristics of
power supply");
-
the equipotential connection of the workplace electri-
cal system to the metal structure of the machine by
means of a copper cable of adequate section (see
position "EQ" in par. E6.2 "Installation diagram");
-
Adducting for the electrical connection between the
workplace electric panel and the equipment;
-
the water supply and drain connections and other
connections as indicated in Table 1 and par. E6
"Plumbing connections";
E2
Characteristics of the place of machine
installation
The machine is designed for installation in professional
and not domestic-type kitchens. Water collection traps/
metal grates must be arranged in the floor at the
machine discharges (see pargraph E6.2 "Installation dia-
gram"), possibly replaceable with a single water trap
sized for a flow rate of at least 0.79 gal/s (3 l/s).
E3

Machine space limits

A suitable space must be left around the machine (for
operations, maintenance, etc.). The passages enabling
personnel to operate on the machine must be at least 19
11/16" (50 cm) wide, except at the rear of the machine.
The size must be increased in case of use and/or trans-
fer of other equipment and/or means or if exit routes are
necessary inside the workplace.

INSTALLATION AND ASSEMBLY

(safety
shoes,
E4

Positioning

The machine must be taken to the place of installation
and the packing base removed only when being
installed.
Arranging the machine:
Wear protective gloves and unpack the machine
(Figure 5).

Figure 5 Unpacking

Lift the appliance using a lift truck, remove the base
and position the appliance where it is to be installed
(Figure 6).
Figure 6 Machine
positioning
Carefully remove the protective film from the outer
panels without tearing it, to avoid leaving traces of
glue (Figure 7).
Adjust the equipment by turning the special adjusta-
ble feet and making sure it is perfectly level, both
lengthwise and crosswise (Figure 8).

Figure 8 Feet adjustment

Figure 7 Removing
the film
13

Publicidad

Tabla de contenido
loading

Productos relacionados para Veetsan VDH63

Tabla de contenido