5. Working room
6. Bathroom
7. Living room
8. Stairwell
Bedrooms: Install a smoke alarm in every bedroom!
Corridors: Install a device in each corridor that leads to a bedroom. If the corridor is longer than 9m, install a
device at the beginning and end of the corridor.
Stairwell: Install a smoke detector on each floor in the stairwell. Smoke and flames can spread particularly
strongly in stairwells!
Living and working rooms as well as storage areas.
Cellar. Mount a smoke alarm detector in the entrance area to the basement.
Rooms with electrical equipment
Attics: When installing smoke alarms on pitched roofs, ensure a minimum distance of 0.5m-1m from the top
of the roof (see Figure 4).
Attics with horizontal ceiling: see Figure 5 for installation
Mount smoke detectors at least 0.5m away from lamps!
Install several smoke alarms in large corridors or large rooms. Observe a maximum distance of 15m!
Install smoke alarms in narrow corridors or rooms no larger than 1m wide in the middle of the ceiling.
Unsuitable mounting locations for smoke alarms:
Rooms with high humidity, e.g. in the bathroom
Garages or kitchens. In the kitchen should be installed a smoke alarm should only if the distance to the
stove is at least 4m.
Smoke detectors should not be installed near heating, heating, cooling and ventilation shafts.
On ceiling beams that are lager than 0.2m
Near open fires or fireplaces
In very dusty rooms.
On A-shaped roofs, the smoke detector must not be mounted at the highest point.
Rooms which have a room temperature below 5°C or above 40°C.
In caravans or rooms with a low ceiling height. Since the air heats up strongly in the upper area due to, for
example, intensive solar radiation in summer, the smoke is prevented from rising to trigger the alarm of the
smoke detector.
Information about the battery:
This smoke detector contains a non-replaceable lithium battery. Under normal conditions the battery has a lifetime
of approx. 10 years. When the battery is running low, a short warning tone sounds every 40 seconds for about 30
days and the LED flashes briefly. During this time the smoke alarm is still fully functional. However, it is strongly
recommended to replace the device immediately! After approx. 30 days the device is no longer functional and
switches off. Replace the device after an operating period of 10 years!
Note: The recurring warning sound can be muted for about 10 hours by pressing the TEST button. After 10 hours, a
short warning tone sounds again every 40 seconds.
General instructions for using batteries:
Danger:
Never expose batteries to extreme conditions, such as heat or strong sunlight! There is an acute risk of
explosion and leakage!
12