Danger:
Make sure that batteries can not be swallowed by children, animals and adults! In particular, keep children
and animals away from this product! If one or more batteries are swallowed, seek medical attention immediately!
Here is an acute danger to life. The substances contained in the battery can cause severe poisoning!
Caution:
Remove leaking batteries from the device immediately! The battery acid contained in the battery can
damage the unit! Avoid direct skin contact with leaking batteries! Wash your hands immediately after contact and
take care that the battery acid does not get into your skin, eyes or mucous membranes! Dispose of leaking and old
batteries according to the regulations.
Replace old batteries with batteries of the same type!
Do not use rechargeable batteries. They have a too low voltage!
Remove the batteries from the battery compartment when you are not using the remote control for more than
a month. Make sure that the battery compartment is always closed when the battery is inserted!
Only operate the device when the battery compartment is closed!
Non-rechargeable batteries are not to be re-charged!
New batteries should not be used together with used batteries!
Always use batteries with the same type!
Never short the terminals of the batteries!
Start up:
Attention:
In order to prevent your hearing from being stressed too much by the very loud alarm tone, do not hold
the device close to your head during the function check! To avoid frightening noise-sensitive persons such as small
children, do not hold the unit in the same room during the function check!
Attention:
Check the function of the smoke detector weekly!
Activation of the smoke detector:
Attach the mounting plate to the back of the unit until it is fully engaged. Then press and hold the TEST button for
about 3 seconds until the LED lights up and a short beep is heard. The smoke detector is now ready for operation.
Functional check:
To check the function, keep the TEST button pressed for approx. 5s. The alarm tone sounds and the LED lights up
red. This is to check whether the electronics, the smoke detector's alarm unit and the battery are functioning. The
alarm tone stops immediately after releasing the TEST button.
Note: If neither the alarm sounds nor the LED flashes, the battery is may be empty or the device may be defective.
Replace it with a new functional device!
Temporary muting the Alarm:
In the event of a false alarm, e.g. caused by heavy smoke development during cooking or high dust levels, the alarm
tone can be muted for approx. 10 minutes. It is essential to ensure that the alarm was not triggered by a fire! To mute
the alarm temporarily, press the TEST button. Then open doors and windows to clean the air. If after 10 minutes the
air still contains a high number of combustion particles, the alarm will sound again. The mute function can be repeated
as often as required by pressing the TEST button. This function cannot be activated if there is excessive smoke. To
deactivate the mute function, press the TEST button!
Recurrent self-test of the smoke alarm detector on its function:
The smoke alarm detector performs every 30-40 seconds a self-test. You can see this by a short blink of the LED.
Explanation of the LED modes :
LED flashes every 40 seconds:
The smoke alarm detector is working properly..