4.
Weighing and counting
4.10 User calibration
Switch scale on and press
f
Enter pin 0000 and press
f
Enter kg unit and press
f
f
f
Use a calibration weight with min. 15% of the weighing range, e.g. for 45 kg weighing range you can use a cali-
bration weight of 5 – 45 kg .
Calibrate in the range where you can get the highest accuracy.
Switch on initialization starts. During this activity unload the scale.
f
while switching on .
.
.
Press
when the unloaded scale is in still stand (arrow sign points to
Place the calibration weight on the scale . Press
stand (arrow sign points to
when the scale is in still
) .
)
.
25