TROUBLE SHOOTING
PROBLEM
Fuse blown or circuit breaker tripped.
Loose electrical connections.
Will not start
Extension cord not correct.
Overheated motor.
Air leak in safety valve.
Low pressure
Restricted air lter.
Defective check valve.
Defective pressure switch or
Safety valve
improper adjustment.
releasing
Improper oil viscosity.
Oil (for oil air
Too much oil in crankcase.
compressor)
Restricted air lter.
Low air ow
Connections leak.
The drain valve is open.
CAUSE
1 YEAR
CORRECTION
Check for cause and replace or reset.
Check wiring connections.
Max.15m/ 50 ft., min. 1.5mm.
Use reset button/wait for automatic reset.
Check valve manually: pull up ward on
rings .If condition persists, replace valve.
Clean or replace air lter.
Replace check valve.
Check for proper adjustment and if
problem persists, replace pressure switch.
Replace with SAE20 or SAE30 non-detergent oil.
Drain crankcase and ll to proper level.
Clean or replace air lter.
Check connection of leakage and repair.
Close the drain valve.
L I M I T E D WA R R A N T Y