Multi-Head PEX Crimp Tool Kit
#23100
Instruction Guide
Crimps conform to ASTM F 1807
Connection Assembly
Cut the tube so that a clean, straight end is provided. Slide the crimp
ring over the tube end. Insert the fitting into the tubing until the
shoulder of the fitting contacts the tubing end. Position the crimp ring
1/8" to 1/4" (3.2 to 6.4 mm) from the cut end of the tubing. Place the
opened jaws of the PEX Crimp Tool around the crimp ring. Check to
be sure that the crimp ring is still properly positioned. Compress the
tool handles to complete the assembly.
CHECK ALL CRIMPS WITH GO/NO-GO GAGE
Gaging Procedure
1.
Determine proper size of tubing: 3/8", 1/2", 3/4" or 1"
2.
If GO cavity fits over crimped ring and NO-GO does not, tool is
crimping properly.
3.
If GO cavity does not fit then handle distance must be increased.
4.
If GO fits—check NO-GO. If NO-GO fits over crimped ring, the ring is
over-crimped, decrease handle distance. Recheck.
NOTE: Over-crimped and under-crimped rings must be removed from
tubing. Crimp with a new copper ring.
Adjustment Procedure
1.
Close tool handles until pre-load is reached (this is the point at
which jaws touch). Tool should not be completely closed.
2.
Measure the distance between dots on the handle ends as shown.
8" - 8-3/4" is the correct distance. If the distance is not 8" - 8-3/4"
the tool must be adjusted.
3.
To change the handle ends distance, remove the #6-32 eccentric
lock screw with an Allen wrench and push up eccentric from back.
Rotate eccentric counter-clockwise to increase the handle distance
and clockwise to decrease handle distance. Move eccentric until
hand distance is between 8" - 8-3/4". Push down eccentric and
re-install the #6-32 lock screw in the appropriate hole which most
closely yields the desired handle distance.
4.
Recheck the set distance after making three crimps. The distance
should be 8" - 8-3/4" between the "dots" on the handles.
5.
Check the crimps with the go/no-go gauge provided. If satisfactory
crimps do not result, the tool is likely worn and should be replaced.
Oetiker, Inc. 6317 Euclid Street, Marlette, Michigan 48453
Info.us.marlette@oetiker.com | +1 800 959 0398 | oetiker.com
sharkbite.com
|
+1 877 700 4242
To insert/remove dies open tool fully and
push up plunger pin from back side of tool.
3/8", 1/2" and 3/4" PEX inserts
(Tool without die set crimps 1")
Tool Maintenance
1.
Check tool calibration daily. It
is recommended that at least
the first and last crimps of the
day are tested.
2.
Never exceed the specified
handle distance when
adjusting your crimp tool.
Premature wear will result.
3.
Lubricate linkages on a regular
basis to maximize tool life.
Warranty
When properly maintained and
used as intended, the PEX Crimp
Ring Tool is warranted against
materials and manufacturing
defects for a period of 1 year from
date of purchase. This Warranty
does not cover defects or
damage arising from improper
installation, lack of or improper
maintenance, improper storage
or handling, ordinary wear and
tear, misuse, abuse or accident,
or use with unauthorized tool
or parts. Liability is limited to
repair or replacement of tool
or component parts which are
determined defective as covered
by this Warranty.
23100INSREV1-21
Eccentric
Lock
Screw
"Dots"
8" - 8-3/4"
Handle Pre Load
Gage all crimps as shown.

Publicidad

loading

Resumen de contenidos para SharkBite 23100

  • Página 1 Multi-Head PEX Crimp Tool Kit #23100 Instruction Guide Crimps conform to ASTM F 1807 Connection Assembly To insert/remove dies open tool fully and push up plunger pin from back side of tool. Cut the tube so that a clean, straight end is provided. Slide the crimp ring over the tube end.
  • Página 2 Kit de Engarzadora para PEX con Cabezales Múltiples 23100 ° Guía de Instrucciones Las engarzadoras cumplen con las especificaciones de ASTM F 1807 Montaje de Conexiones Para insertar o retirar los troqueles, abra la herramienta del todo y levante el pasador Corte el tubo para que el extremo quede limpio y recto.