REMOVE OR REPLACE CARTRIDGE
Turn off hot and cold water supplies
before beginning.
To remove or replace cartridge:
• Turn valve to OFF position.
• Pull out PLUG BUTTON (1) and remove HANDLE SCREW (2).
• Pull off HANDLE (3) and CAP (4).
• Unthread CARTRIDGE NUT (5) and remove.
• Pull out CARTRIDGE (6).
• Inspect CARTRIDGE (6) and O-RINGS (7) for debris and clean if necessary.
• Clean MANIFOLD (8) and rinse clean.
• Reinstall CARTRIDGE (6) and O-RINGS (7) onto CARTRIDGE (6).
• Reinstall CARTRIDGE NUT (5), CAP (4) and HANDLE ASSEMBLY (3).
2
1
2.5mm HEX KEY
REMOVE
5
6
7
7
CARE INSTRUCTIONS
DO: SIMPLY RINSE THE PRODUCT CLEAN WITH CLEAR WATER. DRY WITH A SOFT COTTON FLANNEL
CLOTH.
DO NOT: DO NOT CLEAN THE PRODUCT WITH SOAPS, ACID, POLISH, ABRASIVES, HARSH CLEANERS,
OR A CLOTH WITH A COARSE SURFACE.
3
4
INSTALL
8
3
4
4
5
6
8
7
2
1

Publicidad

loading

Este manual también es adecuado para:

Aspirations 7061131Aspirations 7061104