Motor fault
E-5, E-6
Overload
ovr
protection
Overvoltage
Blank screen
protection
Motor
overheating
hot
protection
In case of any disconnected / loos-
ened wire, motor 1 is faulty and
"rSt" and "E-5" are displayed and
alternately flash on the LED screen;
or motor 2 is faulty and "rSt" and
"E-6" are displayed and alternately
flash on the LED screen.
"ovr" is displayed and flashes on the
LED screen when the load exceeds
the set value (normally the load
should be controlled below 80KG).
The LED screen goes blank when the
input voltage of the controller
exceeds 32V.
The LED screen displays "hot" 2min
after a continuous motor operation.
Normal operation can resume after
a 15min wait.
1. "rSt" and "E-6" are displayed and
alternately flash only for double
columns / only on dual motor desks
2. Check all the wire connections
between the motors and the
controller, make sure they are
secure, and then reset the system
until the LED screen displays the
minimum to clear the alarm.
This alarm can be cleared by removing
the weight from the desktop and
powering off and on the controller.
1. The controller is powered off and
the LED screen goes blank when the
voltage exceeds 32V.
2. The system automatically recovers
and the LED displays the real-time
height when the voltage drops to 32V.
1. Continuous operation implies a
long period of desk motor operation
with intervals less than 3s.
2. This alarm can also be cleared by
powering on the control system
again.