Dial Position
Range
600.0mV/6.000V
Voltage AC
60.00V/600.0V
600.0mV/6.000V
Voltage DC
60.00V/600.0V
Low Input
Lo-Z
Lo-Z
600.0V
Impedance
99.99/999.9Hz
Hz
Hz
Hertz
9.999/50.00kHz
600.0Ω
Resistance
6.000/60.00/600.0kΩ
6.000/40.00MΩ
Cont Buzzer
Continuity
0-600.0Ω
100.0μF
Capacitance
1000μF
0.40mA-60.00mA/600.0mA
Current AC
6.000A/10.00A
0.40mA-60.00mA/600.0mA
Current DC
6.000A/10.00A
- 40.0ºC ~ 400.0ºC
Temperature
†
-40.0ºF ~ 752.0ºF
† Temperature Range, Resolution and Accuracy are for the DMM. Temperature Probe may have different
specifi cations.
* These instruments are True-RMS sensing. All voltage and current readings are True-RMS values.
* Input impedance: Voltage DC: 10MΩ; Voltage AC: 10MΩ // less than 100pF; Lo-z: 4kΩ approximately
* Overload protection:
Voltage DC, Voltage AC, Lo-Z Voltage and Hertz: AC/DC 720V for 10 second
Current DC & Current AC: AC/DC 20A for 10 sec.
Resistance, Continuity, Capacitance and Temperature: AC/DC 600V for 10 second
* Maximum measurement time: 1 minute at 10A, rest time 20 minutes minimum
* Minimum frequency measurement is 2Hz
* Signal voltage in frequency mode: 8V-600V(RMS)
* Minimum AC Current measurement is 0.40mA
* Minimum AC Voltage measurement is 4.0mV
* For AC Voltage, AC Current and Lo-z:
Additional Accuracy by Crest Factor (C.F.):
Add 6.0% for C.F. 1.0 ~ 2.0.
Add 7.0% for C.F. 2.0 ~ 2.5.
Add 9.0% for C.F. 2.5 ~ 3.0
Max. Crest Factor: 1.6 for 6600 ~ 5000 digits
2.0 for 5000 ~ 3000 digits
3.0 for 3000 ~ 0 digits
* Measurement accuracy of square wave and truncated waveforms at 1kHz is unspecifi ed.
Functions
Resolution
Accuracy
0.1mV/0.001V/
±(1.0% + 3 dgt) (45~500Hz)
0.01V/0.1V
±(2.0% + 3 dgt) (500~1000Hz)
0.1mV/0.001V/
±(0.5% + 2 dgt)
0.01V/0.1V
0.1V
±(2.0% + 3 dgt) DC,AC : 45~500Hz
0.01Hz/0.1Hz/
±(0.1% + 2 dgt)
0.001kHz/0.01kHz
0.1Ω
±(1.0% + 5 dgt)
0.001/0.01/0.1kΩ
.001/.01MΩ
±(1.9% + 5 dgt)
Buzzer sounds at 30Ω or less
0.1μF
±(1.9% + 2 dgt)
1μF
0.01mA/0.1mA
±(1.5% + 3 dgt) (45~500Hz)
0.001A/0.01A
0.01mA/0.1mA
±(1.0% + 3 dgt)
0.001A/0.01A
0.1°C
±(1.0% + 10 dgt)
0.2°F
±(1.0% + 18 dgt)
6
ASSEMBLY
WARNING
To avoid an electrical hazard,
turn the Rotary Dial to OFF and disconnect the
test leads before replacing batteries.
Loading/Changing the Batteries
Replace batteries when the Low Battery indicator
is displayed.
1. Turn Rotary Dial to OFF and disconnect the test
leads.
2. Unscrew and remove battery door.
3. Insert two (2) AA
batteries, according to
the polarity marked in
the battery compartment
4. Close the battery door
and tighten four (4)
screws securely.
OPERATION
WARNING
Only use Milwaukee test
leads with the MILWAUKEE DMM. Inspect test
leads for continuity before each use. Do not
use if the readings are high or noisy.
Before Use
Confi rm the Rotary Dial is set to the correct position,
the instrument is set to the correct measurement
mode, and the Data hold function is disabled. Oth-
erwise, desired measurement cannot be made.
LCD Backlight
The LCD backlight will turn off after about 10 min-
utes of inactivity. Press the backlight button
turn the backlight on again.
Making a Measurement
AC Voltage
DANGER
To avoid electrical shock:
Never make measurement on a circuit in
which voltage over AC600V exists.
Do not use with the Battery Cover removed.
Keep fi ngers behind the guards and away
from test lead tips during measurements.
1. Set the Dial to
position.
2. Connect the red test lead
to the VΩ terminal and the
black test lead to the COM
terminal.
3. Connect the test leads to the
circuit under test. The read-
ing is displayed.
CAUTION
Readings may fl uctuate or
be infl uenced in noisy environment.
7