GAS STOVE INSTALLATION:
•
This stove was designed for use with LP gas.
•
Always use a pressure regulator designed specifically for your
gas stove. The lack of a pressure regulator could cause excess
pressure and dangerous gas leakage. Check the pressure
regulator reading frequently to determine that the pressure level
is safe. The hose and regulator should be replaced every 5
years.
•
Use a PVC hose that can handle temperatures from 20° C to 100° C. Be sure
the hose:
• Does not have joints.
• Does not directly touch the back of the stove and is not confined in a tight
area able to trap extremely high temperatures.
• Is less then 125 cm long.
•
If possible, install the gas cylinder outside the kitchen in a
protected place that has good airflow.
•
Use a 1/2 –inch copper pipe to connect to the gas stove.
•
Plastic hoses should never connect to the back of the gas stove.
HOSE INSTALLATION:
•
Place the metal clamp on the hose end.
•
Connect the hose to the oven receptacle and tighten the clamp.
•
Place the other clamp on the opposite hose end and connect it to the pressure
regulator. Tighten the clamp.
•
Bolt the pressure regulator to the gas cylinder carefully.
•
After the installation, check for gas leaks, using soap or liquid detergent.
Adaptor
E ng lis h -6
Pressure Regulator
Metalic Flexible Hose