Descargar Imprimir esta página

Pahlen 125821 Classic Manual Del Usuario página 10

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 23
Outlet
Install outlet nozzle like this:
1. Fix the embedded tubing into the framework of the pool. Recommended mounting depth,
see drawings on the previous page. The flange should rest on the pool wall according to A, B or C
(see previous page.
2. If needed, connect a cable from ground point on the inlet pipe to earth.
3. Mask the flange (the surface that will then lie against the gasket).Cast concrete.
4. Fix self-adhesive packing to the flange of the inlet pipe.
5. Install the pool liner and begin flooding.
6. When the water reaches around 5 cm below the suction outlet nozzle, install the packing (t = 2 mm)
and sealing.
7. Trim the pool liner after the sealing inside edge.
8. Install the front with Pahlén logo on top.
9. Fill the pool with water to the desired level.
Winter storage
1. Remove the front. Store it in a suitable place.
2. The hole should be plugged with a winter plug (not included). Use a plug with conical expander or thread 1½".
10
ENGLISH
UP
Flange
UP
Sealing ring

Publicidad

loading

Este manual también es adecuado para:

125826