Descargar Imprimir esta página

FALMEC E.Ion Gruppo Incasso 50 Manual De Instrucciones página 25

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 34
ELECTRICAL CONNECTION
(only intended for qualifi ed personnel)
Disconnect the equipment from electrical mains power supply before carry-
ing out any operations on the hood.
Ensure that the wires inside the hood are not disconnected or cut:
in the event of damage, contact your nearest Servicing Department.
Refer to qualifi ed personnel for electrical connections.
Connection must be carried out in compliance with the provisions of law in force.
Before connecting the hood to the electrical mains power supply, check that:
voltage supply corresponds with what is reported on the data plate located inside the
hood;
the electrical system is compliant and can withstand the load (see the technical specifi -
cations located inside the hood);
the power supply plug and cable do not come into contact with temperatures exceed-
ing 70 °C;
the power supply system is eff ectively and properly connected to earth in compliance
with regulations in force;
the socket used to connect the hood is within reach.
In case of:
devices fi tted with cables without a plug: the type of plug to use is a ''standardised'' one.
The wires must be connected as follows: yellow-green for earthing, blue for neutral and
brown for the phase. The plug must be connected to an adequate safety socket.
fi xed equipment not provided with a power supply cable and plug, or any other device
that ensures disconnection from the electrical mains, with an opening gap of the con-
tacts that enables total disconnection in overvoltage category III conditions.
Said disconnection devices must be provided in the mains power supply in compliance
with installation regulations.
The yellow/green earth cable must not be cut off by the switch.
The Manufacturer declines all responsibility for failure to comply with the safety regulations.
FUMES DISCHARGE
HOOD WITH INTERNAL RECIRCULATION (FILTERING)
In this version, air passes through zeolite-carbon fi lters and the
E.ION ionising system to be purifi ed and recycled in the environ-
ment. Make sure the zeolite-carbon fi lters are installed in the hood,
otherwise, apply them as indicated in the assembly instructions.
ASSEMBLY INSTRUCTIONS
only intended for personnel qualifi ed
The hood can be installed in various confi gurations.
The generic assembly steps apply to all installations; for each case, follow
the specifi c steps provided for the required installation.
OPERATION
WHEN TO TURN ON THE HOOD?
Switch on the hood at least one minute before starting to cook to direct fumes and vapours
towards the suction surface.
After cooking, leave the hood operating until complete extraction of all vapours and odours.
By means of the Timer function, it is possible to set auto switch-off function which will allow
the hood to turn off automatically after 15 minutes of operation.
AIR QUALITY
Air quality is displayed by the colour of the leaf.
Green = excellent quality.
Yellow = pollutant agents found.
The higher the number of pollutant agents, the darker the yellow
colour.
WHICH SPEED IS TO BE SELECTED?
1st speed: maintains the circulation of clean air with low electricity consumption.
2nd speed: normal conditions of use.
3rd speed: presence of strong odours and vapours.
WHEN SHOULD THE FILTERS BE WASHED OR REPLACED?
The metal fi lters must be cleaned every 30 hours of operation.
The zeolite-carbon fi lters must be reactivated every 18 months and replaced every 3 years.
For further details see the "MAINTENANCE" chap.
TOUCH PUSHBUTTON PANEL
Motor ON/OFF
Upon start-up, the speed is that stored at the previous operation.
Increase speed from 1 to 3
Riduzione velocità da 3 a 1
Automatic cycle: the hood only activates when pollutant agents are found.
The function deactivates if:
- no pollutant agents are found for 3 hours;
- The TIMER key (
) is pressed again.;
- keys + and - are pressed
Light on/off
TIMER (
red LED fl ashing)
Auto switch-off after 15 min.
The function deactivates (red LED off ) if:
- The TIMER key (
) is pressed again.
- The ON/OFF key (
) is pressed.
FILTER ALARM
(Red LED on with (
Anti-grease fi lter maintenance after approximately 30 hours of operation.
Press (
) for 3 seconds to reset.
MAINTENANCE
Before cleaning or carrying out maintenance operations, disconnect the
equipment by removing the plug or switching off the main switch.
Do not use detergents containing abrasive, acidic or corrosive substances
or abrasive cloths.
Regular maintenance guarantees proper operation and performance over time.
Special attention is to be paid to the metal anti-grease fi lters : frequent cleaning of the
fi lters and their supports ensures that no fl ammable grease is accumulated.
CLEANING OF EXTERNAL SURFACES
You are advised to clean the external surfaces of the hood at least once every 15 days to
prevent oily substances and grease from sticking to them.
Alternatively and for all the other types of surfaces, it can be cleaned using a damp cloth,
slightly moistened with mild, liquid detergent or denatured alcohol.
Finish off cleaning by rinsing well and drying with soft cloths.
Do not use too much water next to the push button control panel and
lighting devices in order to prevent humidity from reaching electronic
parts.
The glass panels can only be cleaned with specifi c, non-corrosive or non-abrasive deter-
gents using a soft cloth.
The Manufacturer declines all responsibility for failure to comply with these instructions.
CLEANING OF INTERNAL SURFACES
It is forbidden to clean electrical parts, or parts related to the motor inside
the hood, with liquids or solvents.
For the internal metal parts, see the previous paragraph.
20
The speeds are indicated by the LEDs
on the keys:
Speed 1
Speed 2
Speed 3
) off )

Publicidad

loading