Trouble
Sluggish operation
Loss of power
Loss of efficiency
SAVE THESE INSTRUCTIONS. DO NOT DESTROY.
MAINTENANCE SECTION
TROUBLESHOOTING GUIDE
Probable Cause
Dirt or oil gum accumulationon
internal parts
Worn Valve
Worn Piston and/or accessory
Solution
Pour about 3 cc of a clean, suitable, cleaning
solution into the air inlet and operate for
30 seconds. After flushing, pour about 3 cc of oil
into the air inlet and operate the tool for 5 seconds
to coat the internal parts with oil.
Replace the Valve.
Replace Piston and or accessory.