Operation
Welding with the Geberit
ESG Light electrofusion tool
The Geberit ESG Light electrofusion
tool is equipped with an automatic
mechanism which prevents a double
weld when a coupling connection
cable is connected.
The required welding time is adjusted
automatically in accordance with the
ambient temperature.
Prerequisite
Pipes, fittings and welding joints are dry
and free of dirt.
Pipes and fittings are prepared in
accordance with the installation manual
for Geberit electrofusion sleeve
couplings.
Pipe surfaces are prepared in
accordance with the installation manual
for Geberit electrofusion tape for anchor
point.
22
WARNING
Danger of death from electric
shock
▶ Do not weld wet or water-
filled pipes.
▶ An isolation transformer
must be included in the
circuit when carrying out
electrofusion work in damp
areas.
CAUTION
Risk of injury from burns
▶ Do not touch the
electrofusion sleeve
coupling or electrofusion
tape, plug contacts and pipe
during the welding
procedure or during the
cooling-down phase.
ATTENTION
Leaking connection caused by faulty
welding
▶ The pipe to be welded must be kept in
a tension-free position during the
welding procedure and the cooling-
down phase.
▶ Air draughts through the pipe interior
must be avoided.
63050397048849803 © 02-2023
967.779.00.0(02)

Publicidad