Technical data
Operating data
Flow rate
Water pressure (recommended)
Water pressure (max.)
Water temperature (max.)
Hole size for faucet
Certifies this faucet complies with ASME A112.18.1 / CSA B125.1, NSF/ANSI/CAN 61‑2020
(AB100 compliant, Q<1 ) & NSF 372. The faucet also complies with water usage
requirements of the California Energy Comission and the US Department of Energy.
Installation instructions
1. Remove all contents from the package
and check for completeness.
2. Turn off water supply.
3. Cut mounting hole 1- 3/8" diameter
(35 mm) in the desired position (if one
isn't available).
4. Place the Rubber O-ring (2) over the
mounting shank.
2A
1
2
Attention: The Rubber O-ring (2) should
be sitting between the countertop and
faucet base.
Do not use putty or other sealant at this
location.
Notes: Solid surface installation: The
countertop mounting surface needs to
be flat and free of debris, otherwise the
faucet may not sit properly.
Value
60 PSI
1.75 gpm
30-85 PSI
2-6 bar
115 PSI
8 bar
158 °F
70 °C
1 3/8"
35 mm
For tile installations avoid installing faucet
near or on top of grout lines. This may
cause a weak joint between the faucet
and the counter and could cause leaks.
5. Install the mounting hardware to
the Faucet Base (1) underneath the
mounting surface in the following
order: Rubber Washer (3), Plastic Flange
(4) and the Fixing Plate (5) (fig. 2B).
2
2B
3
4
5
6
7 Nm
5
EN
200-600 kPa
800 kPa