NOTE: The red dot next to power level indicator will flash。
b). Once the countdown timer expires, the corresponding zone will switch off. Then it will show the new
min. timer and the dot of corresponding zone will flash.
c). When cooking timer expires, the corresponding
cooking zone will be switch off automatically.
Note:
a) The red dot next to power level indicator will illuminate indicating that zone is selected.
b) If you want to change the time after the timer is set, you have to start from step 1.
3.3.7 Over-Temperature Protection
A temperature sensor equipped can monitor the temperature inside the ceramic hob. When an
excessive temperature is monitored, the ceramic hob will stop operation automatically.
3.3.8 Residual Heat Warning
When the hob has been operating for some time, there will be some residual heat. The letter
" H "appears to warn you to keep away from it.
3.3.9 Default working times
Another safety feature of the hob is automatic shutdown. This occurs whenever you forget to switch off a
cooking zone. The default shutdown times are shown in the table below:
Power level
Default working timer (hour)
(set to 15 minutes)
(set to 5 minutes)
1
2
3
4
8
8
8
4
15
5
6
7
8
4
4
2
2
9
2