WIKA LSD-30 Manual De Instrucciones página 10

Interruptor de nivel
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

3. Specifications
3.3 Output signal
Switching output 1
PNP
GB
PNP
PNP
PNP
PNP
Alternatively also available with NPN rather than PNP switching output.
Offset adjustment (display)
max. +1,500 mm
Scaling (display and analogue signal)
Zero point: max. +25 % of span
Final value: max. -25 % of span
Analogue signal
Load
Current output: ≤ 500 Ω
Voltage output: > 10 kΩ
10
Switching output 2
-
-
PNP
PNP
PNP
Switching output
Switching point 1 and 2 are individually adjustable
Function
Switching voltage:
Switching current:
Response time:
Adjustment accuracy: 2.5 mm steps
WIKA operating instructions level switch model LSD-30
Analogue signal
4 ... 20 mA
DC 0 ... 10 V
-
4 ... 20 mA
DC 0 ... 10 V
Normally open and
normally closed:
Window and hysteresis: freely adjustable
Power supply – 1 V
max. 250 mA per
switching output
< 200 ms
freely adjustable

Publicidad