Wiring; Commissioning; Programming The Rts Control Point; Operation - SOMFY Ramp RTS-HR1 Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 43
Heating Mod/Var Ramp RTS-HR1

4. Wiring

CAUTION! Comply with current standards and legislation when installing.
Ensure that the total power of the heating lamp(s) connected to the Heating Mod/Var Ramp RTS-HR1
does not exceed 2000 W.
The line must be protected by a 16 A delay fuse (minimum).
Faulty supply cables must only be replaced by the supplier, the supplier's customer service team or a
qualified professional, to avoid any danger.
-
Connect the Heating Mod/Var Ramp RTS-HR1 to an available 230V socket.

5. Commissioning

The Heating Mod/Var Ramp RTS-HR1 is commissioned using an RTS control point.
For more accurate and optimised use of the Heating Mod/Var Ramp RTS-HR1, Somfy recommends
using a control point from the Telis Mod/Var RTS range.
Caution! If the installation comprises several Heating Mod/Var Ramp RTS-HR1s, only one Heating
Mod/Var Ramp RTS-HR1 should be connected at a time!
Caution! Do not use the Inis RT/RTS control point for commissioning. These control points are not
suitable for commissioning.

5.1 Programming the RTS control point

1)
Press the Up and Down buttons on the RTS control point
simultaneously until the heating lamp comes on then goes out.
2)
Briefly press the PROG button on the RTS control point: the heating
lamp will come on then go out again to indicate that the RTS control
point has been programmed into the Heating Mod/Var Ramp
RTS-HR1.

6. Operation

The building in which the product is used might reduce the radio range. This range is:
X = 200 m in open space
Y = 20 m through 2 concrete walls
Caution! The use of a radio appliance (e.g. Hi-Fi radio headphones)
operating on the same frequency may cause interference and be
detrimental to the product's performance.
Before changing the direction of the heat supply, switch off the
equipment and wait until it has cooled down.
Never leave the Heating Mod/Var Ramp RTS-HR1 unsupervised while
it is on!
Do not cover the Heating Mod/Var Ramp RTS-HR1 while it is on and wait until it has cooled down to
prevent any risk of fire!
The Heating Mod/Var Ramp RTS-HR1 can be used to select 3 different levels of heating:
The heating lamp heats to 33% power,
The heating lamp heats to 66% power,
The heating lamp heats to 100% power.
N.B.: The default factory setting for the favourite heating level on the Heating Mod/Var Ramp RTS-HR1
is 33% of maximum power. This favourite position may be modified as required.

6.1 With a Mod/Var range RTS control point

1) To switch on the heating ramp:
-
Press the Up button:
36
1
2
1
Copyright © 2008-2010 Somfy SAS. All rights reserved.
Installation guide
PROG.
X
Y
ON

Publicidad

Tabla de contenido
loading

Tabla de contenido