OPERATING
GB
CONTROL PANEL
The control panel is made-up of three LED, a 7 segment display and a button:
POWER LED, CHARGE PHASE LED (BULK, ABSORPTION, FLOAT) ERROR LED, STATUS display and ON/
STAND-BY button (see fig.4).
FIG.4
ON/STAND-BY BUTTON:
Use this button to put the battery charger in stand-by mode. To activate this mode simply press the but-
ton quickly (press and release in less than one second). To take the battery charger out of stand-by mode,
press the button quickly again or disconnect the battery charger from the AC power supply and then
connect it up again.
The information supplied by the LEDS are listed as below:
POWER LED
LED COLOUR
DESCRIPTION
OFF
No mains power
Green
Power ON
Flashing
Battery charger in stand-by mode
CHARGE PHASE LED
LED COLOUR
DESCRIPTION
No output power
OFF
BULK PHASE - charge at constant current
Red
ABSORPTION PHASE - charge at constant voltage
Orange
FLOAT PHASE - float charge
Green
ERROR LED
LED COLOUR
DESCRIPTION
No problem with manual reset
OFF
Problem with manual reset (see error codes)
Red
22