uNloAdING THe Tool
WARNING:
engaged whenever any adjustments are made or when tool is not in use.
1. Press the pusher latch (9) and pull the magazine down.
2. Tip the tool over until the staples slide freely out of the magazine.
AdjuSTING dePTH (fIG. 5)
The depth that the fastener is driven can be adjusted using the depth adjustment
wheel (3) on the side of the tool.
WARNING:
attempting to adjust depth, ALWAYS:
• Remove battery pack.
• Engage trigger lock-off.
• Avoid contact with trigger during
adjustments.
Depth settings are on a sliding scale, the
right side being the shallowest and the
left side being the deepest.
1. To drive the staple shallower, rotate the
depth adjustment wheel (3) to the lowest
setting, towards the right on the depth
adjustment indicator (4).
2. To drive the staple deeper, rotate
the depth adjustment wheel (3) to the
highest setting, towards the left on the depth adjustment indicator (4).
WoRk lIGHTS (fIG. 6)
There are work lights (5) located on each side of
the stapler. Work lights turn on upon depressing the
contact trip (7).
NoTe:
These work lights are for illuminating the
immediate work surface and are not intended to be
used as flashlights.
loW BATTeRy INdIcAToR: The work lights will
flash and then turn off completely to indicate low battery.
jAMMed STAPle INdIcAToR: The work lights will flash continually if a staple
becomes jammed in the nose piece (see clearing a jammed staple).
STAll ReleASe (fIG. 7)
WARNING:
reset it. To do so, follow instructions on clearing the jammed staple. Next remove
battery pack and then reinsert battery pack. The tool will now be operational.
If the stapler is used in rigorous application where all available energy in the motor is
used to drive a fastener, the tool may stall. The driver blade will not complete the drive
cycle and the jam/stall indicator will flash. Rotate the stall release lever (6) on the tool and
the mechanism will release as shown in figure 7.
NoTe:
The tool will disable itself and not
reset until the battery pack has been removed
and reinserted. If the driver blade does not
automatically return to the home position, proceed
to "clearing a jammed staple, fig. 8". If the unit
continues to stall please review the material and
fastener length to be sure that it is not too rigorous
an application.
The battery should always be removed and the trigger lock-off
To reduce risk of serious injury from accidental actuation when
If a jam occurs, the tool will disable itself and will require you to
5
4
3
6
7
12
5
6