English
Before
Charge
charging
status
lamp (RED)
While
charging
Charging
complete
Charging
impossible
Overheat
Overheat
lamp
standby
(GREEN)
NOTE: When standby for cooling battery, UC36YRL cools the overheated battery by cooling
fan.
Regarding the temperature of the rechargeable battery.
The temperatures for rechargeable batteries are as shown in the table below, and
batteries that have become hot should be cooled for a while before being recharged.
Rechargeable batteries
BSL2530, BSL3626
Regarding recharging time
Table 4 shows the recharging time required according to the type of battery.
Battery Voltage
25.2V
36V
NOTE: The recharging time may vary according to the ambient temperature.
10
Indications of the pilot lamp
Blinks
Lights for 0.5 seconds. Does not light
(RED)
for 0.5 seconds. (off for 0.5 seconds)
Lights
Lights continuously
(RED)
Lights for 0.5 seconds. Does not light
Blinks
for 0.5 seconds. (off for 0.5 seconds)
(RED)
Lights for 0.1 seconds. Does not light
Flickers
for 0.1 seconds. (off for 0.1 seconds)
(RED)
Lights
Lights continuously
(GREEN)
Table 4 Recharging time (approx. min.) at 20°C
2.6 Ah
—
BSL3626
Table 2
Table 3
Temperatures at which
the battery can be recharged
Battery capacity (Ah)
Li-ion BATTERY
—
80min.
Malfunction in the
battery or the charger
Battery
overheated.
Unable
to
(Charging will commence
when battery cools).
32°F—122°F (0°C — 50°C)
3.0 Ah
BSL2530
60min.
—
charge
—