30°С, and OFF status is possible as well.
f.
To store the point, shortly press the "Timer" button;
then you are automatically transferred to the setting of
the next point (the display again shows dAYX) and you
can proceed with paragraph а) for the next point.
g.
When you have stored a point in the last hour of the
day – 23.5h, you cannot store any more points for this
day in the current setting, and the display will show
"FUL_" and the number of the day.
ATTENTION: Points of a particular day may be
stored only in ascending order of their times.
Note: Before implementing paragraph f) the user can go
back to paragraph а) to correct the three parameters of
a point by shortly pressing the ON/OFF button, without storing
the settings in the memory.
Adding more points in a particular day may be done
at random, after you have stored points for other days,
however you need to observe the rule for ascending
order of their times in a day.
To exit the settings mode, press continuously the
"Timer" button and wait for 30 seconds.
Upon leaving the settings you can review the stored
points by using the
and
the appliance is in programming mode.
Note: When you turn on the appliance, it will start
operating in the (heating or programming) mode which
it has last operated.
Note: You can switch between the modes of operation
(heating or programming) by shortly pressing the
"Timer" button when the appliance is switched on.
"Return to factory settings" function
When the convector is in "Off" mode, press the
buttons simultaneously for six seconds; then the
display will show „_ _ __" and rotating symbols. When
it is "reset", the display will show the measured value of
the room temperature.
After using the reset function, you need to re-enter the
settings of the following functions:
time setting
enter a value of the temperature correction (if needed)
disable the "Anti-frost" function (if needed)
disable the "Adaptive start" (if needed)
weekly programme - 24/7
If the electric convector is disconnected from the
mains, this will not affect the set temperature and the
mode of operation which has been active prior to its
disconnection. If for example the convector has been
in "Heating" mode, after it has been disconnected and
reconnected to the mains, it will continue operating in
the same mode with the same set temperature.
English
buttons, provided that
and
The principle of operation of the electric
convector with energy-independent memory is to
store the settings for 90 minutes guaranteed, and up to
150 minutes not guaranteed.
When the room temperature is lower than the
temperature set by the electronic thermoregulator,
the convector will start operating and will continue
operating until the room temperature reaches the set
value. When the room temperature is higher than the
temperature set by the electronic thermoregulator, the
convector will automatically go into "Standby" mode.
Information presented on panel heater display
Indications when you are not in settings mode:
a.
In Off mode – consecutively showing:
time (hour and minutes)
measured room temperature
b.
In Heating mode – it shows the measured room
temperature
c.
In Programming mode – consecutively showing:
Day of the week, low line and the measured
temperature. 6_22
Day of the week, low line and the temperature set in
the programme blinking (set for the current hour),
which may be also the OFF symbol. 6_23
d.
Upon connecting the convector to power supply the
display shows:
Hyphens "----", if the appliance has been in Off mode
before disconnecting it from the power supply.
Hyphens "----", which in 2 seconds will be
replaced by the value of the current temperature,
if the appliance has been in On mode before
disconnecting it from the power supply.
e.
Two numerals (01÷96) and a blinking yellow LED
indicate the remaining time in hours until the delayed
start, if the appliance has been in "Delayed start"
mode before disconnecting it from the power supply.
f.
With the purpose of further energy saving, the
electronic thermoregulator reduces the brightness
of illumination of all LEDs. Upon pressing any of the
buttons the brightness increases for 8 seconds and it is
then reduced again.
g.
If the display shows "t0" or "t1", this means that the
self-diagnostic system has found a problem with the
temperature sensor. "t0" indicates a disconnected
cable at the sensor, while "t1" indicates short circuit
at the sensor. In this case the electric convector will
be automatically switched off and it can be switched
on again only after the problem has been fixed. The
problem has to be handled by a qualified specialist.
h.
Upon switching on the power supply the display
will show hyphens "----" for 2 seconds instead of
temperature of time.