Ducting conducts
Closely follow the instructions set out in this manual.
All responsability, for any eventual inconveniences, damages or fires caused by not complying with the instructions in this
manual, is declined.
Vertical Discharge
Use a rectangular duct 3
/
" x 10" (8.3 x 25.4 cm) and a 3
1
4
(8.3 x 25.4 cm) rectangular transition for discharge of fumes to the
outside.
D
A
A. 3
/
" x 10"
(8.3 x 25.4 cm)
1
4
rectangular transition
B. 3
/
" x 10"
(8.3 x 25.4 cm)
duct
1
4
Preparation
Do not cut a joist or stud unless absolutely necessary. If a joist or
stud must be cut, then a supporting frame must be
constructed.
Fittings material is provided to secure the hood to most types of
walls/ceilings.
However, a qualified technician must verify suitability of the
materials in accordance with the type of wall/ceiling.
Before making cutouts, make sure there is proper clearance
within the ceiling or wall for exhaust vent.
CAUTION
For gas cooktop & range installations: Mount the hood so the
bottom is at least 30" (76.2 cm) above the cooking surface.
For electric/induction cooktop & range installations:
Installation
Ducting Version
After having chosen the vent option, proceed as follows:
• Prepare duct and conduit cut outs as needed.
• If possible, disconnect and move freestanding or slide-in
range from cabinet opening to provide easier access to rear
wall.
Otherwise put a thick, protective covering over countertop,
cooktop or range to protect from damage and debris. Select
a flat surface for assembling the unit. Cover that surface with
a protective covering and place all canopy hood parts and
hardware in it.
6
/
" x 10"
1
4
C
B
A
B
C. Cabinet
D. 90° elbow
Horizontal Discharge
Use a rectangular duct 3
/
"x10" (8.3x25.4 cm) for discharge of
1
4
fumes to the outside.
C
A. 3
/
" x 10"
(8.3 x 25.4 cm)
1
4
B. 3
/
" x 10"
1
4
Mount the hood so the bottom is at least 24" (61 cm) above the
cooking surface.
There is no maximum mounting height, however, we recommend
mounting the hood no greater than 36" (91.4 cm) above the
cooking surface. For every inch (2.54 cm) above 36" (91.4 cm),
fume and moisture capture efficiency diminishes at an increa-
sing rate and may not deliver an acceptable level of ventilating
performance.
This hood is intended for household use.
PLEASE READ THE INSTALLATION MANUAL FOR SPECIFIC
APPLICATION. Check your ceiling height and hood height
before selecting your hood.
• Determine and mark the centerline on the wall where the
canopy hood will be installed. Select a mounting height
comfortable for the user and mark on wall.
• Prepare duct and conduit cut outs as needed.
B
A
rectangular transition
(8.3 x 25.4 cm)
duct
C. Cabinet