OPERATION
Before performing a leak test, be sure that no sparks can occur and you are in a spacious outdoor
area. Connect the propane gas tank to the regulator and turn the valve on the unit to the "off"
position. Brush a soap and water mixture on all connections. Turn the gas supply on; if bubbles
occur on any connection there may be a leak. If you smell gas or a leak is discovered turn the
gas valve off, disconnect propane gas tank and do not use the appliance until the leak is
repaired.
Do not use the heating unit without inspecting the gas hose. If there are signs of wear or abrasion
you must replace the hose (if applicable). Pumice stones/lava rocks/LavaGlass™ could pop up and
20 minutes after igniting. Flame height should be a yellow/blue color between 2 - 10 inches in height.
heating item.
To Light
1. Make sure the control knob (F) is in the "off" position. Slowly open the valve on the propane gas
tank by turning the knob counterclockwise.
2. Push and hold in the control knob (F) and turn it to the "pilot" position, continue to hold.
3. Press the electronic ignit r (G) to ignite the pilot burner. After the pilot burning is lit, keep holding
4. Let go of the control knob (F) and rotate to the "low" or "high" position to light the main burner.
5. If the pilot burner does not light within a few seconds, release the control knob (F) and rotate
to the "OFF" position. Wait for 5 minutes for gas to clear and then repeat the above lighting
instructions.
To Extinguish
1. Turn control knob (F) clockwise to the "pilot" position; let the knob pop up and continue turning
the control knob (F) to the "off" position.
2. Close the cylinder valve on the propane gas tank if you don't intend to use it for a long time.
WARNING
Fire product and propane gas cylinder minimum
distance must be over 60 inches (as per right side
photo)
Bond Manufacturing Company | Page 8
60"