Alarm function is available on temperature controller. By default, this
will signal any deviation of more than 3°C from the set temperature.
Alarm sound can be muted by pressing any button (alarm will be still
signalized by the display blinking and symbol 14 lit).
Remote control
Thermal unit installation can contain remote dashboard control. If
installed, some specific conditions apply:
Remote display has priority in control of temperature. If
connected, the display on the thermal unit cannot be used
for setting of temperature and is not taking part in
temperature regulation.
The same rules as described in section "controls" apply to
the remote display (including setting of temperature in the
box)
Do not use power switch on thermal unit. This switch should
be in position "0" all the time. Use switch on remote control
to operate the unit.
Master/slave operation
If the box volume requires it, the box can be equipped with 2 thermal
units connected in series. This allows higher volumes to be
controlled. The first unit in the chain becomes the master device,
and this is the only device that shows or controls the temperature in
the box. The master device can be either the remote control or
thermal unit. The other units are connected with control cables and
their operation is synchronized with the master device. The display
of these so called slave units remains switched off. Power needs to
be supplied to each unit individually.
TUC1800/2000-usm. rev.01
© 2020 VebaBox B.V. User Manual VebaBox+TUC1800 or TUC2000
15