TEC40D
➤ Mount the gaskets (available as accessory) to the casing and fix them with the
srews (fig. 3, page 4).
➤ Position the casing in the desired area and attach it with the appropriate screws
(fig. 4, page 4).
➤ Insert the engine plate into the casing and screw it into place (fig. 5, page 4).
➤ Mount the casing cover and attach it with the pins (fig. 6, page 4).
9.3
Attaching the exhaust pipe
Observe the following instructions when installing the exhaust pipe:
• Do not create any sharp bends which will inhibit the flow of exhaust fumes.
➤ Connect the hose (fig. 7 2, page 5) to the muffler (fig. 7 1, page 5) and attach
it with the clamps (fig. 7 4, page 5)
➤ Secure the exhaust pipe extension to the vehicle floor (fig. 7 3, page 5).
9.4
Installing the tank and fuel supply line
Please observe the following instructions for the installation location:
• The tank bottom must be positioned at a maximum of 1 m below the bottom of
the generator.
• The top of the tank must not be higher than the top of the generator.
• The maximum horizontal distance between generator and fuel tank is 3 m.
• Lay the fuel hoses as straight as possible (fig. 8, page 5).
➤ Secure the tank, see fig. 8, page 5 and chapter "Connecting the float" on
page 21.
➤ Connect the fuel hose (fig. 9 1, page 6) to the fuel filter (fig. 9 2, page 6).
➤ Connect the hose to the fuel return (fig. 9 3, page 6).
➤ Secure the hoses with clamps.