8. Electrical work
[Fig. 8-2-5] (P.6)
Ⓐ Indoor terminal block
Ⓑ Earth wire (green/yellow)
Ⓒ Indoor/outdoor unit connecting wire 3-core 1.5 mm
Ⓓ Outdoor terminal block
Ⓔ Power supply cord
① Connecting cable
2
Cable 3-core 1.5 mm
, in conformity with Design 245 IEC 57.
② Indoor terminal block
③ Outdoor terminal block
④ Always install an earth wire (1-core 1.5 mm
⑤ Remote controller cable
2
Wire No × size (mm
) : Cable 2C × 0.3
This wire accessory of remote controller
(wire length : 10 m, non-polar. Max. 500 m)
⑥ Wired remote controller (option)
⑦ Power supply cord
• Perform wiring as shown in [ Fig. 8-2-5] (P.6). (Procure the cable locally.)
Make sure to use cables of the correct polarity only.
• Connect the terminal blocks as shown in [ Fig. 8-2-5] (P.6).
Caution:
• Use care not to make mis-wiring.
• Firmly tighten the terminal screws to prevent them from loosening.
• After tightening, pull the
ires lightly to confirm that they do not move.
8.3. Remote controller (wired remote controller (option))
8.3.1. For wired remote controller
1) Installing procedures
Refer to the installation manual that comes with each remote controller for details.
2) Function selection of remote controller
If two remote controllers are connected, set one to "Main" and the other to "Sub".
For setting procedures, refer to "Function selection of remote controller" in the
operation manual for the indoor unit.
8.4. Remote controller (wireless remote controller
(SEZ-DAL2 Series))
8.4.1. For wireless remote controller
Refer to the installation manual that comes with each remote controller for details.
8.4.2. Signal Receiving Unit
1) Sample system connection
[Fig. 8-4-1] (P.6)
Indoor/outdoor wiring
Signal receiving unit wiring
Ⓐ Outdoor unit
Ⓑ Refrigerant address
Ⓒ Indoor unit
Ⓓ Signal receiving unit
Only the wiring from the signal receiving unit and between the remote controllers is
shown in [Fig. 8-4-1]. The wiring differs depending on the unit to be connected or
the system to be used.
For details on restrictions, refer to the installation manual or the service handbook
that came with the unit.
1. Connecting to Mr. SLIM air conditioner
(1) Standard 1:1
① Connecting the signal receiving unit
Connect the signal receiving unit to the CN90 (Connect to the wireless remote
controller board) on the indoor unit using the supplied remote controller wire.
Connect the signal receiving units to all the indoor units.
2) Setting the pair number switch
[Fig. 8-4-2] (P.6)
<Indoor controller board>
1. Setting method
Assign the same pair number to the wireless remote controller as that of the
indoor unit. If not doing so, the remote controller cannot be operated. Refer to
the installation manual that came with the wireless remote controller for how to
set pair numbers of wireless remote controllers.
Position of daisy wire on the controller circuit board on the indoor unit.
Controller circuit board on the indoor unit (reference)
[Fig. 8-4-2] (P.6)
Ⓐ CN90: Connector for remote controller wire connection
18
2
or more
2
) longer than other cables
For pair number settings, the following 4 patters (A-D) are available.
Pair number
Pair number on
setting pattern
remote controller side
A
0
B
1
C
2
D
3~9
2. Setting example
(1) To use the units in the same room
[Fig. 8-4-3] (P.6)
① Separate setting
Assign a different pair number to each indoor unit to operate each indoor unit
by its own wireless remote controller.
[Fig. 8-4-4] (P.6)
② Single setting
Assign the same pair number to all the indoor units to operate all the indoor
units by a single wireless remote controller.
[Fig. 8-4-5] (P.6)
(2) To use the units in different rooms
Assign the same pair number to the wireless remote controller as that of the
indoor unit. (Leave the setting as it is at purchase.)
3) How To Install
[Fig. 8-4-6] (P.7) to [Fig. 8-4-13] (P.8)
1. Common items for "Installation on the ceiling" and "Installation on the
switch box or on the wall"
[Fig. 8-4-6] (P.7)
Ⓐ Signal receiving unit external
Ⓑ Center of Switch box
Ⓒ Switch box
Ⓓ Installation pitch
[Fig. 8-4-7] (P.7)
Ⓐ Remote controller wire
Ⓑ Hole (drill a hole on the ceiling to pass the remote controller wire.)
Ⓒ Signal Receiving Unit
(1) Select the installation site.
The following must be observed.
① Connect the signal receiving unit to the indoor unit with the supplied remote
controller wire. Note that the length of the remote controller wire is 5 m (16
ft). Install the remote controller within the reach of the remote controller wire.
② When installing on either the switch box or the wall, allow space around the
Signal Receiving Unit as shown in the figure in [Fig. 8-4-6].
③ When installing the Signal Receiving Unit to the switch box, the Signal
Receiving Unit slipped downward for 6.5 mm (1/4 inch) as shown in the
figure in [Fig. 8-4-6].
④ Parts which must be supplied on site.
Switch box for one unit
Thin-copper wiring pipe
Lock nut and bushing
⑤ The thickness of the ceiling to which the remote controller is installed must
be between 9 mm (3/8 inch) and 25 mm (1 inch).
⑥ Install the unit on the ceiling or on the wall where the signal can be received
from the wireless remote controller.
The area where the signal from the wireless remote controller can be
received is 45° and 7 m (22 ft) away from the front of the signal receiving
unit.
⑦ Install the signal receiving unit to the position depending on the indoor unit
model.
⑧ Connect the remote controller wire securely to the order wire. To pass the
remote controller wire through the conduit, follow the procedure as shown in
Fig. 8-4-8.
[Fig. 8-4-8] (P.7)
Ⓐ Fix tightly with tape.
Ⓑ Remote controller wire
Note:
• The point
here the remote controller
on the indoor unit model.
Take into account that the remote controller wire cannot be extended when
selecting the installation site.
• lf the Signal Receiving Unit is installed near a fluorescent lamp specially
inverter type, signal interception may occur.
Be careful for installing the Signal Receiving Unit or replacing the lamp.
2. Installation on the switch box or on the wall
(1) Use the remote controller wire to connect it to the connector (CN90) on
the controller circuit board on the indoor unit.
Indoor controller circuit board side Point
where the daisy wire is disconnected
Not disconnected
J41 disconnected
J42 disconnected
J41 and J42 disconnected
Ⓔ 6.5 mm (1/4 inch)
Ⓕ 70 mm (2 - 3/4 inch)
Ⓖ 83.5 ± 0.4 mm (3 - 9/32 inch)
Ⓗ Protrusion (pillar, etc)
Ⓒ Order wire
ire is connected differs depending