SMART AUTOMATION BY-ME PLUS
01850.2
Actuator with 16 A 120-230 V~change-over relay output, for con-
trolling trhe pump circulation, installation on DIN rail (60715 TH35),
occupies 2 modules sized 17.5 mm.
CHARACTERISTICS.
• Rated supply voltage: BUS 29 V
• Input: 14 mA
• Dissipated power: 1,5 W
• Changeover relay output
• Controllable loads at 120-230 V~ (contact NO):
- resistive loads:
16 A (20.000 cycles)
- incandescent lamps: 10 A (20.000 cycles)
- fluorescent lamps and energy saving lamps: 1 A (20.000 cycles)
- electronic transformers: 4 A (20.000 cycles)
- ferromagnetic transformers: 10 A (20.000 cycles)
• Controllable loads at 120-230 V~ (contacts NC and NO):
- motors cos ø 0.6: 3,5 A (100.000 cycles)
• Terminals:
- TP bus
- relay contacts (NO, C and NC)
• 2 modules of 17.5 mm.
• The device can moreover be installed on walls, conduits, ceilings and false
ceilings.
MANUAL MANAGEMENT
Pressing the manual button
enables using the button to actuate the relay.
All the messages from the bus are ignored. In normal operation, pressing the
relay actuation button is ignored.
CONFIGURATION.
FOR THE OPERATIONS OF CONFIGURATION, SEE THE INSTRUCTIONS MANUAL FOR THE
By-me Plus SYSTEM.
• Functional blocks: 1.
• Selecting the functional block (configuration): during application creation, when is
requesting you to press the device button:
- press the configuration button and the LED will light up;
- with the LED on, the app VIEW Pro will configure the functional unit; at the end of
this operation the LED will go out.
PARAMETERS.
• one- or two-position stable operation;
• on delay and off delay: a value between 0 and 200 gives the time in seconds, a value
between 201 and 250 gives the time in minutes (for example 201 = 1 minute, 202 =
2 minutes, etc.);
Monostable operation.
On delay: delay in closing the NO contact of the relay from receiving the close com-
mand.
Off delay: time for which the relay has the NO contact closed.
Bistable operation.
On delay: delay in closing the NO contact of the relay from receiving the ON com-
mand.
Off delay: delay in opening the NO contact of the relay from receiving the OFF com-
mand.
• If a group is created with a number of relays in one-position stable mode, set for
all the same on and off delays and do not insert any other types of actuator in the
same group; in this way, it is possible to have the status of the one-position stable
relay indicated on the control button. For special requirements it is possible to use
the group depth (for example to switch on two-position stable relays or dimmers with
a single button).
• Default parameters: relay set on two-position stable operation with null on and off
delay.
• The actuator 01850.2 can also be used as a relay for the pump or for the main cir-
culation valve in a multi-zone heating system that must be controlled via the By-me
system. In this case, the device can belong to max 64 groups.
INSTALLATION RULES.
Installation should be carried out by qualified staff in compliance with the current
regulations regarding the installation of electrical equipment in the country where the
products are installed.
49400102A0 07 2201
FRONT VIEW AND CONNECTIONS.
NO NC
C
NO C NC
OUT 1
By-me
Manual
management button
INSTALLATION
NC
C
NO
1
O UT
1
O UT
0. 2
01
85
H
IT C
S W
O R
AT
TU
A C
A
16
~
µ
23 0V
12 0-
.
NF
m e
CO
B y-
S
BU
FIGURE 1.
ON delay
ON delay
ON
Control
ON
ON delay
Control
Control
ON
OFF
The relay output power circuit must be protected against overcurrents by installing
a device, a fuse with a rated breaking capacity of 1500 A or a type-C circuit breaker,
with rated current not exceeding 16 A.
CONFORMITY.
LV directive. EMC directive. Standard EN 50428.
REACH (EU) Regulation no. 1907/2006 – Art.33. The product may contain traces
of lead.
WEEE - Information for users
If the crossed-out bin symbol appears on the equipment or packaging, this means the product
must not be included with other general waste at the end of its working life. The user must take
the worn product to a sorted waste center, or return it to the retailer when purchasing a new one.
Products for disposal can be consigned free of charge (without any new purchase obligation) to
retailers with a sales area of at least 400 m
waste collection for the environmentally friendly disposal of the used device, or its subsequent
recycling, helps avoid the potential negative effects on the environment and people's health, and
encourages the re-use and/or recycling of the construction materials.
Led and button
OUT 1
to actuate the relay
01850.2
SWITCH
ACTUATOR
16A
120-230 V~
Led and
CONF.
Configuration button
BUS
+
-
BUS line
MONOSTABLE
OFF
BISTABLE
OFF delay
2
, if they measure less than 25 cm. An efficient sorted
Viale Vicenza, 14
36063 Marostica VI - Italy
www.vimar.com