Installation (continued)
PLACEMENT
Move the assembled unit to its final location. Final hook up of the
supply lines and drain system can now be completed .
SUPPLY LINES (NOT INCLUDED)
The supply lines that attach the faucet to the household water system,
are not supplied with this unit . They need to be purchased separately .
Follow the manufacturers instructions for proper installation of the
supply lines .
Maintenance
CARTRIDGE REPLACEMENT
1 . Before proceeding, turn off the water supply to the faucet .
2 . Take off the plastic water indicator by hand, then use the Allen
key to remove the screw and pull out the handle body . The top
lever of the cartridge will be exposed .
3 . Unscrew the cap and rings, making sure not to damage the
threads .
4 . Pull out the cartridge and replace it with a new 35 mm
(1 .4 in .) ceramic cartridge .
5 . Replace the rings and the cap .
6 . Place the handle body on the cartridge . Lock the screw onto
the handle body and tighten it with the Allen key . Do not over
tighten .
7 . Put the plastic water indicator back into the hole, make sure the
red is on the left and blue is on the right .
Cartridge
Faucet body
10
Water indicator
Screw
Cap
Rings
Handle
body

Publicidad