- GB -
− The unit may only be connected when the electrical data of the unit and the power supply coincide. The unit data is
to be found on the unit type plate or on the packaging, or in this manual.
− Ensure that the unit is fused for a rated fault current of max. 30 mA by means of a fault current protection device.
− Extension cables and power distributors (e. g. outlet strips) must be suitable for outdoor use.
− Ensure that the power connection cable cross section is not smaller than that of the rubber sheath with the identifi-
cation H05RN-F. Extension cables must meet DIN VDE 0620.
− Protect the plug connections from moisture.
− Only plug the unit into a correctly fitted socket.
Safe operation
− Never operate the unit if either the electrical cables or the housing are defective!
− Do not carry or pull the unit by its electrical cable.
− Route cords/hoses/lines in a way that they are protected against damage, and ensure that they do not present a
tripping obstacle.
− Only open the unit housing or its attendant components, when this is explicitly required in the operating instructions.
− Only execute work on the unit that is described in this manual. If problems cannot be overcome, please contact an
authorised customer service point or, when in doubt, the manufacturer.
− Only use original spare parts and accessories for the unit.
− Never carry out technical modifications to the unit.
− The power connection cables cannot be replaced. When the cable is damaged, the unit or the component needs to
be disposed of.
− Only operate the unit if no persons are in the water!
− Keep the socket and power plug dry.
Important! The unit is equipped with a permanent magnet. The magnetic field may affect the function of pace-
makers.
Installation
Attention! Dangerous electrical voltage.
Possible consequences: Death or severe injury.
Protective measures:
− Prior to reaching into the water, disconnect the power supply to all units used in the water.
− Disconnect the power plug prior to carrying out work on the unit.
Screw T distributor to the connection socket, screw nozzle tube to the T distributor (A1). Screw nozzle mounting and
the desired water feature nozzle to the nozzle tube (A2). It is possible to connect a hose to the lateral outlet at the T
distributor by means of the reduction element and the stepped hose connection (A3). Place the unit in the pond hori-
zontally on firm, sludge-free ground and ensure that it is completely covered with water (at a maximum of 2 m below
the water level).
Align the nozzle tube. The water feature height and the water flow can be adjusted with a regulator at the lateral outlet
at the T distributor (B). The power supply must be disconnected to switch off the unit.
Start-up
Attention! Sensitive electrical components.
Possible consequence: The unit will be destroyed.
Protective measure: Do not connect the unit to a dimmable power supply.
Attention! The pump must never run dry.
Possible consequence: The pump will be destroyed.
Protective measure: Check the water level at regular intervals. Always place the unit below water level.
Attention! The installed temperature monitor automatically turns the pump off, if it is overloaded. The pump
automatically switches on again once the motor has cooled down. Risk of accident!
This is how to connect the power supply:
Switching on: Connect power plug to the socket. The unit switches on immediately when the power connection is
established.
Switching off: Disconnect the power plug.
8